7.0 SAFETY CUTOUT SYSTEM

This product has one non-self-resetting overheat protection device (thermal cut-out) which will activate if the air inlets or
out-lets are obstructed. For safety reasons the fire will NOT switch on again automatically, the following procedure must be
carried out before the fire can be operated.
NOTE: The visual effect will remain operational if the cutout is activated, only the fan heater is prevented from working. Switch
OFF the appliance at the wall socket or outlet. Leave the fire OFF for a period of no less than 10 minutes, ensuring all
obstructions are removed. Switch the appliance ON at the wall. Ensure the appliance is turned ON at the control switches.
If the fire fails to operate correctly, repeat the above procedure. If an attempt to switch on the appliance is made before the
safe-ty cutout has reset, the appliance may cutout for a further period of time. If the sequence has been followed correctly
and the appliance still fails to function, check the fuse in the wall outlet. If this is not the cause, call an electrician or maintenance
engineer.

8.0 MAINTENANCE

ALWAYS DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY BEFORE
Excluding lamps and fuses, use only genuine spare parts available from your supplier. Replacement lamps must be of the
same wattage and specification as those stated in Section 3.0 Appliance Data.
Replacing the light bulbs.
The LED lights inside the appliance are not replaceable.

9.0 CLEANING

There is no specific requirement for care of the fire other than a regular cleaning of the general appliance.
A wipe with a dry cloth is normally sufficient. DO NOT use abrasive cleaners as they can damage the finish. Brass and silver
parts of the fire may be cleaned using a appropriate metal polishes.
10.0 SPARES
Refer to Section 3.0 Appliance Data for lamp and fuse specification. Excluding lamps and fuses, use only genuine manufacturers
spare parts available from your supplier.
11.0 SERVICING
There are no internal user serviceable parts.
Check regularly for security of wall fixings as appropriate. Also check security of supply cable and connections. If the supply cable
becomes damaged, it must be replaced by a service agent or competent person, such as a qualified electrician.
This appliance is supplied with a BS1363 3 pin plug fitted with a 10 Amp fuse. Should
the fuse require replacing, it must be replaced with a fuse rated at 10 Amp and
approved to BS1362. In the event of the mains plug being removed/ replaced for any
reason, please note : IMPORTANT: The wires in the mains lead are coloured in
accordance with the following code:
Blue - Neutral
Brown - Live
Green/ Yellow - Earth
As the colours of the wires in the mains lead of this appliance may not correspond
with the colour markings identifying the terminals in your plug, proceed as follows.
The blue wire must be connected to the terminal marked with an N or coloured
black. The brown wire must be connected to the terminal marked with an L or coloured red. The green/yellow wire must be
connected to the earth terminal which is marked with an E or with the earth symbol. WARNING: Never connect live or
neutral wires to the earth terminal of the plug.
NOTE: If a moulded plug is fitted and has to be removed take great care in disposing of the plug and severed cable, it must be
destroyed to prevent engaging into a socket.
Refer to Section 3.0, Appliance Data for fuse specification. Excluding fuses, use only genuine manufacturers spare parts available
from your supplier.
12.0 TROUBLESHOOTING GUIDE
Fire is not switching on
Fire is not emitting any heat
Fire shuts off after a period of time
UNDERTAKING ANY MAINTENANCE.
Ensure the mains switch is on
Replace the fuse in the plug
The fire is fitted with an energy saving thermostat. If the temperature in the room is
higher than the temperature selected on the fire, then the thermostat will stop the
heater from turning on.
Check that the temperature is not set onto the lower settings. If the room is warm
enough the thermostat will stop the fire switching the heat on.
Check that the chimney/ flue is blocked off.
5
GREEN/ YELLOW
Earth
BLUE
Neutral
Cord Clamp
©
2021 Focal Point Fires Ltd.
GB IE
BROWN
Live
FUSE
10 Amps
10 Amps