Wrap the connection point firmly with Teflon tape to ensure a good seal and to prevent leaks.
Remove the air filter and pour a small amount of water into the drain pan to make sure
that water flows from the unit smoothly.
G
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according to the following figures.
CORRECT
Make sure there are no
kinks ordent in drain hose to
ensure proper drainage.
NOT CORRECT
Kinks in the drain hose will
create water traps.
Plug the unused drain hole
To prevent unwanted leaks you must plug the unused
drain hole with the rubber plug provided.
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS
1.
All wiring must comply with local and national electrical codes, regulations and must
be installed by a licensed electrician.
2.
All electrical connections must be made according to the Electrical Connection Diagram
located on the panels of the indoor and outdoor units.
3.
lf there is a serious safety issue with the power supply, stop work immediately. Explain your
reasoning to the dient, and refuse to install the unit until the safety issue is properly resolved.
4.
Power voltage should be within 90-110% of rated voltage. lnsufficient power supply can
cause malfunction, electrical shock, or fire.
5.
lf connecting power to fixed wiring, a surge protector and main power switch should
be installed.
6.
lf connecting power to fixed wiring, a switch or circuit breaker that disconnects all poles
and has a contact separation of at least 1/8in (3mm) must be incorporated in the fixed wiring.
The qualified technician must use an approved circuit breaker or switch.
NOT CORRECT
Kinks in the drain hose will
create water traps.
NOT CORRECT
Do not place the end of the
drain hose in water or in
containers that collect wa-
ter. This will prevent proper
drainage.