together. See Fig.4.9.
Fig. 4.9
6.
After f inishing connecting the couple of the quick connectors, pass drain hose and refrigerant pipes
through the wall hole as shown in Fig.4.10
NOTE: The quick connector parts must be placed outside of room. Using wall hole sleeve, cap and
neoprene to seal the wall hole.
Fig. 4.10
7.
In order to prevent the quick connector parts from being exposed in the air, the sound deadening
pads are supposed to be used during the installation, see Fig.4.11.
Fig. 4.11
8.
Wrap up the quick connectors with the sound deadening pads, pack down the pads solid as tightly
as shown in Fig.4.12
Fig. 4.12