User Programming Mode Flow Chart; Diagnostic Programming Mode Flow Chart - Pentair FLECK NXT2 Service Manual

Table of Contents

Advertisement

DAY OVERRIDE/TIME-DRIVEN
Example:
10 D
Range: Off - 99 Days
MASTER PROGRAMMING MODE
REGEN. TIME
Example:
Range: 0 - 23 Hours 59 Minutes.
FLOW CHART continued...
02:OOHR
Example:
LOCK WINDOW #1
ON
Start Lock Window
OFF
End Lock Window
BACKWASH
Example:
10 M
Range: 0 - 240 M
DRAW
Example:
60 M
Range: 0 - 240 M
RAPID RINSE
Example:
10 M
Range: 0 - 240 M
TANK REFILL
Example:
12 M
Range: 0 - 240 M
PAUSE
Example:
0 M
Range: 0 - 240 M
METER TYPE
Example:
0.75" TURBINE
1.00" PADDLE
Paddle (0.75", 1", 1.5", 2", 3")
1.00" TURBINE
Turbine (0.75", 1.25", 1.5")
Generic
Example:
CONTINUOUS FLOW DETECT
ON
Range: 0.1 to 999.9 gpm/Lpm
OFF
AUXILIARY 1
Example:
STANDBY
OFF
Off, Alarm Based, Cycle Based, Time Based,
ALARM BASED
Volume Based, Standby
AUXILIARY 2
Example:
STANDBY
OFF
Off, Alarm Based, Cycle Based, Time Based,
ALARM BASED
Volume Based, Standby
PUSH SETTINGS
OFF
ON
SAVE AS NON-FACTORY
ON
OFF
LOCK SETTINGS
Example:
TIME BASED
OFF
Off, Delayed, Enter Code, Time Based
DELAYED
END
10 • Pentair Fleck NXT2 Timer
USER PROGRAMMING MODE
FLOW CHART
User Programming Mode
1. Press and hold the Down and Up buttons simultaneously for
3 seconds to enter the User Programming mode.
2. To navigate the menu, press the Extra Cycle button to
advance to the next value. Press the Left button to retreat to
the previous value.
3. Where applicable, use the Up and Down buttons to adjust a
value as desired.
4. After progressing through all available values, the timer
will return to Normal operation.
5. To exit diagnostic mode, progress through all cycles, or
press & hold Left button at any time, or simply wait 5
minutes and timer will automatically return to normal
operation.
6. Depending on the current controller settings, certain values
may not be able to be viewed or set.
7. The timer will display local information, not system
information.
8. In the event of a regeneration occurring while displaying
user programming, the regeneration step and time
remaining will be displayed. When regeneration has been
completed, the display will return to the main screen.
DAY OVERRIDE/TIME-DRIVEN
Example:
10 D
Range: Off - 99 Days
REGEN. TIME
Example:
02:OOHR
Range: 0 - 23 Hours 59 Minutes.
HARDNESS - GPG
Example:
025
Range: 1 - 999 grains per gallon
VOLUME REMAINING - G
Example:
09999
Range: 1 - 99999 gallons
END
DIAGNOSTIC PROGRAMMING MODE
FLOW CHART
Diagnostic Programming Mode
1. Press and hold the Left button to enter Diagnostic
Programming mode.
2. To navigate, press the Extra Cycle button to advance to the
next value. Press the Left button to retreat to the previous
value.
3. Where applicable, use the Up and Down buttons to adjust a
value as desired.
4. To reset/clear a value (such as Totalizer or Error Log),
while on the value, press and hold the Up and Down buttons
simultaneously.
5. After progressing through all available values, the timer
will return to normal operation.
6. To exit diagnostic mode, press and hold the Left button at
anytime or after 5 minutes of inactivity the timer will return
to normal operation automatically.
7. Depending on the current controller programming, certain
values may not be able to be viewed or modified.
8. The timer will display local information, not system
information.
9. In the event of a regeneration occurring while displaying
diagnostics, the regeneration step and time remaining will
be displayed. When regeneration has been completed, the
display will return to the main screen.
Example:
FLOW RATE
29.7 GPM
Real-time flow rate reading.
Example:
PEAK FLOW
30.1 GPM
Peak flow since last regeneration.
Example:
TOTALIZER
482474 G
Gallons at the outlet since installation.
Example:
RESERVE
1588 G
Reserve Capacity setting.
Example:
USE SINCE REGEN
7331 G
Gallons at the outlet since last regeneration.
Example:
LAST REGEN.
4 H
Time since last regeneration.
Example:
SOFTWARE VERSION
13026
Installed software version.
Example:
NO. OF REGENS
32
Total number of regenerations since installation.
Example:
REGEN INTERVAL
3 D 21 H
Duration between regenerations.
Example:
LAST SETTINGS CHANGE
14 H 0 M
Last time programming settings were changed.
Example:
ERROR LOG
Record of error events chronologically.
ERROR LOG EMPTY
14 H 0 M
Last time programming settings were changed.
Example:
ERROR LOG
Record of error events chronologically.
ERROR LOG EMPTY
Example:
SUN-AVERAGE USAGE
29.7 G
Average usage from past Sunday.
SUN-DAILY USAGE
Example:
2017-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Sundays.
2017-12-26 0 G
Example:
MON-AVERAGE USAGE
Average usage from past Monday.
29.7 G
MON-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Mondays.
2016-12-26 0 G
Example:
TUE-AVERAGE USAGE
29.7 G
Average usage from last Tuesday.
TUE-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Tuesdays.
2016-12-26 0 G
Example:
WED-AVERAGE USAGE
29.7 G
Average usage from last Wednesday.
WED-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Wednesdays.
2016-12-26 0 G
Example:
THU-AVERAGE USAGE
29.7 G
Average usage from last Thursday.
THU-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Thursdays.
2016-12-26 0 G
Example:
FRI-AVERAGE USAGE
29.7 G
Average usage from last Friday.
FRI-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Fridays.
2016-12-26 0 G
Example:
SAT-AVERAGE USAGE
29.7 G
Average usage from last Saturdays
SAT-DAILY USAGE
Example:
2016-10-10 0 G
2017-01-02 0 G
Average usage from past 3 Saturdays.
2016-12-26 0 G
END
Pentair Fleck NXT2 Timer • 11