  • Page 1 FLECK SXT TIMER SERVICE MANUAL waterpurification.pentair.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS JOB SPECIFICATION SHEET TABLE OF CONTENTS ............2 Job Number: ______________________________________________ JOB SPECIFICATION SHEET ..........2 Model Number: ____________________________________________ California Proposition 65 Warning ........2 Water Hardness: __________________________________ ppm or gpg TIMER FEATURES ..............3 Capacity Per Unit: __________________________________________ TIMER OPERATION ..............4 Mineral Tank Size: ___________ Diameter: ________Height: ________ MASTER PROGRAMMING MODE CHART ......5 Salt Setting per Regeneration: ________________________________...
  • Page 3: Timer Features

    TIMER FEATURES Setting the Time of Day 1. Press and hold either the Up or Down buttons until the Parameter Data programming icon replaces the service icon and the Display Display Indicator parameter display reads TD. Error/ Information Icon 2. Adjust the displayed time with the Up and Down buttons. 3.
  • Page 4: Timer Operation

    TIMER OPERATION Manually Initiating a Regeneration 1. When timer is in service, press the Extra Cycle button for Meter Immediate Control 5 seconds on the main screen. A meter immediate control measures water usage and regenerates the system as soon as the calculated system 2.
  • Page 5: Master Programming Mode Chart

    MASTER PROGRAMMING MODE CHART CAUTION Before entering Master Programming, please contact your local professional water dealer. To enter Master Programming, set time to 12:01 PM. Master Programming Options Abbreviation Parameter Option Options Abbreviation Gallons Display Format Liters dF1b Downflow/Upflow Single Backwash dF2b Downflow Double Backwash Fltr...
  • Page 6: Master Programming Mode

    MASTER PROGRAMMING MODE 2. Valve Type (Display Code VT) When the Master Programming Mode is entered, all available option setting displays may be viewed and set Press the Extra Cycle button. Use this display to set the Valve as needed. Depending on current option settings, some Type.
  • Page 7: Master Programming Mode Continued

    MASTER PROGRAMMING MODE CONTINUED 8. Reserve Selection (Display Code RS) Press the Extra Cycle button. Use this display to set the Safety 5. Tank in Service (Display Code TS) Factor. Use this display to select the type of reserve to be used in your system.
  • Page 8: Master Programming Mode Continued

    14. Day of Week Settings MASTER PROGRAMMING MODE CONTINUED Press the Extra Cycle button. Use this display to set the 11. Day Override (Display Code DO) regeneration schedule for a system configured as a Day of Press the Extra Cycle button. Use this display to set the Week control.
  • Page 9: User Programming Mode

    USER PROGRAMMING MODE 5. Press the Extra Cycle button. Use this display to adjust the Fixed Reserve Capacity. This option setting is identified by “RC” or "SF" in the upper left-hand Corner User Programming Mode Options of the screen. Abbreviation Parameter Description Day Override...
  • Page 10: Diagnostic Programming Mode

    DIAGNOSTIC PROGRAMMING MODE 5. Press the Up button. Use this display to view the Volume Used since the last regeneration cycle. This option setting is identified by “VU” in the upper left hand corner Diagnostic Programming Mode Options of the screen. Abbreviation Parameter Description...
  • Page 11: 2510/2750/2850S Timer Assembly

    2510/2750/2850S TIMER ASSEMBLY 9C 9D 42778 Rev E Item No. Part No. Description 1 ....1 ..13881 ....Bracket, Hinge Timer 3 ....1 ..14265 ....Clip, Spring 4 ....1 ..27172 ....Stand-off, Timer, 2510SXT, 2750SXT 5 ....1 ..21363 ....Screw, Hex HD, M4 X 12 MM 7 ....1 ..
  • Page 12: 9000/9100/9500 Twin Tank Timer Assembly

    9000/9100/9500 TWIN TANK TIMER ASSEMBLY 42777 Rev D Item No. Part No. Description 1 ....1 ..13881 ....Bracket, Hinge Timer 2 ....2 ..11384 ....Screw, Phillips, 6-32 X 1/4 3 ....1 ..42732 ....Bracket, Timer, 9000SXT 4 ....2 ..13296 ....Screw, Hex Washer Hd, 6-20 X 1/2 5 ....1 ..
  • Page 13: 3/4-Inch Plastic Turbine Meter Assembly

    3/4-INCH PLASTIC TURBINE METER ASSEMBLY 19797 Rev A Item No. Part No. Description 1 ....1 ..19791-01 ..Meter Cable Assembly, 16 inch long with connector 2 ....2 ..19569 ....Clip, Flow Meter 3 ....2 ..13314 ....Screw, Slot Ind Hex, 8-18 x .60 4 .......
  • Page 14: Plastic Paddle Meter Assembly

    PLASTIC PADDLE METER ASSEMBLY BR60086 Rev E Item No. Part No. Description 1 ....1 ..14716 ....Meter Cap Assy, NT (includes items 2, 3, and 4) 2 ....1 ..13874 ....Cap, Meter, Electronic 3 ....1 ..13847 ....O-ring, -137, Std, Meter 4 ....1 ..
  • Page 15: 3/4-Inch Brass Paddle Meter Assembly

    3/4-INCH BRASS PADDLE METER ASSEMBLY Item No. Part No. Description 1 ....1 ..11206 ....Gasket, Fitting 2 ....1 ..13942 ....Retainer, Nut 3 ....1 ..11207 ....Nut, Special, Quick Connect 4 ....1 ..13906 ....Body, Meter, 3/4-inch 5 ....1 ..13509 ....Impeller, Meter ..
  • Page 16: 1-Inch Brass Paddle Meter Assembly

    1-INCH BRASS PADDLE METER ASSEMBLY Item No. Part No. Description 1 ....1 ..14959 ....Body, Meter, 2750 2 ....1 ..13882 ....Post, Meter Impeller 3 ....1 ..13509 ....Impeller, Meter 4 ....1 ..13847 ....O-ring, -137, Std/560CD, Meter 5 ....1 ..14716 ....Meter Cap Assy, ET/NT 6 ....4 ..
  • Page 17: 1-Inch Stainless Steel Meter Assembly

    1-INCH STAINLESS STEEL METER ASSEMBLY Item No. Part No. Description Item No. Part No. Description 4 ....1 ..19791 ....Meter Cable Assembly, 1 ....1 ..62049-01 ..Service Kit, ..19791-02 ..Meter Cable Assembly, 1 inch & 1-1/2 inch Meter, 28 inch long with connector Standard Range ..
  • Page 18: Inline Plastic Turbine Meter Assembly

    INLINE PLASTIC TURBINE METER ASSEMBLY Item No. Part No. Description Item No. Part No. Description 16 ....1 ..19791 ....Meter Cable Assembly, 1 ....1 ..17542 ....Flow Straightener ..19791-02 ..Meter Cable Assembly, 2 ....2 ..40576 ....Clip, H, Plastic, 7000 28 inch long with connector 3 ....1 ..
  • Page 19: 1-1/2 Inch Brass Meter Assembly

    1-1/2 INCH BRASS METER ASSEMBLY Item No. Part No. Description ..60611-23 ..Meter Assy, 1-1/2 Inline, BSP, STD, inch Paddlewheel, Sleeve to 1-inch ..60611-23NP..Meter Assy, 1-1/2 inch Inline, BSP/MET STD, Nickel Plated, Paddlewheel, 1-inch Sleeve 12 ..... 60610-02 ..Meter Assy, 1-1/2 , NPT, inch STD, Brass Paddlewheel...
  • Page 20: 1-1/2 Inch Stainless Steel Meter Assembly

    1-1/2 INCH STAINLESS STEEL METER ASSEMBLY Item No. Part No. Description Item No. Part No. Description 4 ....1 ..19791 ....Meter Cable Assembly, 1 ....1 ..62049-01 ..Service Kit, 1 inch & 1-1/2 inch Meter, ..19791-02 ..Meter Cable Assembly, Standard Range 28 inch long with connector 1 ..
  • Page 21: 3/4-Inch, 1-Inch Or 1-1/2 Inch Paddle Wheel Meter Cap Assembly

    3/4-INCH, 1-INCH OR 1-1/2 INCH PADDLE WHEEL METER CAP ASSEMBLY Item No. Part No. Description 1 ....1 ..14716 ....Meter Cap Assy, NT 2 ....1 ..19121-01 ..Meter Cable Assy, SXT, Paddle 6700XTR ..19121-08 ..Meter Cable Assy, NT, 35-inch w/Connector ..
  • Page 22: Troubleshooting

    TROUBLESHOOTING Error Codes Error codes appear on the In Service display. NOTE: Error Code Error Type Cause Reset and Recovery Cam Sense The valve drive took longer Unplug the unit and examine the powerhead. Verify that all cam Error than 6 minutes to advance to switches are connected to the circuit board and functioning the next regeneration position properly.
  • Page 23: 2510Sxt Wiring Diagram

    2510SXT WIRING DIAGRAM 42741 Rev B FLECK • 23 SXT Timer Service Manual...
  • Page 24: 2750Sxt/2850Sxt Wiring Diagram

    2750SXT/2850SXT WIRING DIAGRAM 42742 Rev B 24 • FLECK SXT Timer Service Manual...
  • Page 25: 9000Sxt/9100Sxt/9500Sxt Wiring Diagram

    9000SXT/9100SXT/9500SXT WIRING DIAGRAM 42743 Rev A FLECK • 25 SXT Timer Service Manual...
  • Page 26: Service Assemblies

    SERVICE ASSEMBLIES Meter 60086-50 .....Meter Assy, 3/4-inch, Electronic 2510/6600/6700 60613 ......Meter Assy, 2750 Electronic 1-inch 60613-20 .....Meter Assy, 2750, Electronic 1-inch BSP/Metric 60613NP ......Meter Assy, 2750, Electronic 1-inch Nickel Plated 60614 ......Meter Assy, 2850/9500, Electronic 1-1/2 inch Meter 60614NP ......Meter Assy, 2850/9500, Electronic 1-1/2 inch Meter, NP 60618 ......Meter Assy, Electronic, 3/4-inch 60619-20 .....Meter Assy, 1-1/2 inch Electronic BSP/...
  • Page 27 FLECK • 27 SXT Timer Service Manual...
  • Page 28 For a detailed list of where Pentair trademarks are registered, please visit waterpurification.pentair.com/brands. § Pentair trademarks and logos are owned by Pentair plc or its affiliates. Third party registered and unregistered trademarks and logos are the property of their respective owners.