TW20_NS20_EW20 Series Weighing Indicator Operation Manual
Tare Operation:
1
Load weight on the platform.
2
Press
key. Zero is displayed, and tare is subtracted.
3
Remove weight on the platform. Tared weight is displayed. It can set only one tare value. It will be shown with
a minus value.
4
This Tare value can be cleared by pressing
cannot take place, if the platter is in in motion.

5.4.2 Automatic tare

The weight of any container can be tared automatically ,to enable automatic tare function, see parameters
2.ADVANCED SETTINGS >3. TARE SETTINGS > 1.AUTO TARE >ON.
1
Load a container on the platform, it will be heard a "beep" sound.
2
ZERO indicator and TARE indicator appears.
3
Zero is displayed in NET window,the subtracted value appears in the tare window.
4
Load the weight in the container,the NET window shows net value with a "beep" sound.
5
Remove weight from the platform. Tared weight is displayed. It can set only one tare value.
6
Remove the container from the platform,display show zero with a "beep" sound.

5.4.3 Pre-set tare

5.4.3.1 Store Pre-set Tare
Direct pre-set tare:
1
Hold T key (
Weighing mode,the digits in Tare window will be active.
(T1~T4 available for TW20 )
2
Using numeric keys to input the tare value.
3
Press
key to confirm,the preset tare value appears.
to
)2 seconds in normal
key, when there is no load on the platter. This tare entry
- 19 -