Global Power Technologies
SCREEN 5: Engine Cranks/Starts and Battery Voltage
Line 1 – Total cumulative number of engine crank attempts.
Line 2 – Total cumulative number of successful engine starts.
Line 3 – Blank.
Line 4 – Voltage of the MX System battery.
SCREEN 6: Electrical - Voltages, Currents, and Frequency
Line 1 – Alternator L1 Line Voltage (V) and Current (A) values.
Line 2 – Alternator L2 Line Voltage (V) and Current (A) values.
Line 3 – Alternator L3 Line Voltage (V) and Current (A) values.
Line 4 – Alternator AC Frequency (Hz).
SCREEN 7: Electrical - Real Power and Apparent Power
Line 1 – Alternator L1 Real Power (kW) and Apparent Power (kVA)
Line 2 – Alternator L2 Real Power (kW) and Apparent Power (kVA)
Line 3 – Alternator L3 Real Power (kW) and Apparent Power (kVA)
Line 4 – Alternator Total System Real Power (kW) and Apparent Power (kVA)
SCREEN 8: Electrical - Power Factors and Line-to-Line Voltages
Line 1 – Alternator L1 Power Factor, and L1-L2 Phase Voltage (V)
Line 2 – Alternator L2 Power Factor, and L2-L3 Phase Voltage (V)
Line 3 – Alternator L3 Power Factor, and L3-L1 Phase Voltage (V)
Line 4 – Alternator Overall System Power Factor
302672 Rev2 | MX PrimeGen
E N G
C R A N K S
E N G
S T A R T S
B A T T E R Y
2 6 . 8 3
L 1
1 2 0 . 0 V
L 2
1 2 0 . 2 V
L 3
1 1 9 . 9 V
F R E Q U E N C Y
L 1
2 . 0 0 1 k W
L 2
1 . 9 9 8 k W
L 3
2 . 0 0 0 k W
T O T A L
5 . 9 9 k W
P F 1
1 . 0 0
P F 2
0 . 9 9
P F 3
0 . 9 8
P F
A v g
0 . 9 9
1 3 7
1 0 8
V o l t s
1 6 . 6 7 A
1 6 . 6 5 A
1 6 . 6 6 A
6 0 . 0 H z
2 . 0 0 1 k V A
2 . 0 1 8 k V A
2 . 0 4 1 k V A
5 . 9 9 k V A
L 1 L 2
2 0 8 . 2 V
L 2 L 3
2 0 8 . 0 V
L 3 L 1
2 0 7 . 9 V