Page 1
Model 716174 3300 Watts 7000 Watts QUESTIONS? If any section of the manual is not understood, please contact Global Industrial Customer Service at 1-800-645-2986 or visit www.globalindustrial.com with any questions or concerns. Danger: Read Safety Information and Entire Manual Before Use...
QUICK-START GUIDE READ MANUAL BEFORE OPERATING YOUR GENERATOR DANGER: OPERATE GENERATOR OUTSIDE ONLY 1.Unplug all electrical devices; Set air switch breaker “off” 2. Add engine oil and gasoline; Turn fuel valve “on” 3. Pull choke lever out to “Start” 4. Insert key into panel lock 5.
NOTICE REGARDING EMISSIONS The United States Environmental Protection Agency (US EPA) and California Air Resources Board (CARB) for engines/equipment certified to California standards, requires that the engine/equipment complies with exhaust and evaporative emissions standards. Locate the emissions compliance decal on the engine to determine applicable standards. It is important to follow the maintenance specifications in the manual to ensure that the engine complies with the applicable emissions standards for the duration of the product’s life.
Page 5
DANGER: The exhaust system must be properly maintained. Do not alter or modify the exhaust system as to render it unsafe or make it noncompliant with local codes and/or standards. Failure to do so will result in death or serious injury. WARNING: The exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
The frame of the generator shall be connected to an approved grounding electrode. PARTS / TECHNICAL DATA Model 716173 Model 716174 ITEM NAME HANDLE MUFFLER FUEL GAUGE...
Page 7
ITEM NAME STARTER SWITCH VOLTMETER GFCI SOCKET (120V / 20A) L14-20R (120V/240V / 20A) ELECTROMAGNETIC CIRCUIT BREAKER USB SOCKET GROUNDING BOLT Model 716174 7000 Watts ITEM NAME STARTER SWITCH VOLTMETER ELECTROMAGNETIC CIRCUIT BREAKER USB SOCKET GROUNDING BOLT L14-30R (120V/240V / 30A)
Page 8
Model 716173 Model 716174 AC Rated Output Running Wa s: 3000W 6500W AC Maximum Output Motor Star ng Wa s: 3300W 7000W AC Voltage 120V / 240V 120V / 240V AC Frequency 60Hz 60Hz Rated VAC Amperage 25A / 12.5A...
Install frame foot as shown in Figure 1-1. Place frame foot assembly (D) under frame. Secure with bolts (E) and nut (F). Model 716174 7000 Watts Install handle as shown in Figure 2-2. NOTE: The wheels are not intended for over- Slide bolts (G) through frame and the-road use.
The following section describes steps necessary to prepare the generator for use. If after reading this section, you are unsure about how to perform any of the steps please call Global Industrial Customer Service at 1-800-645-2986 or visit www.globalindustrial.com. Failure to perform these steps properly can damage the generator or shorten its lifespan.
Step 2 - ADD GASOLINE DANGER: Fuel and vapors are extremely flammable and explosive. Add fuel in a well ventilated area and keep fire and spark away. Failure to do so could result in death or serious injury. A nearby open flame can lead to explosion even if not directly in contact with gasoline. DANGER: Do not overfill fuel tank.
OPERATION Before starting the generator, make sure you have read and performed the steps in the “Generator Set-up” section of this manual. If you are unsure about how to perform any of the steps in this manual, please call 1-800-645-2986 or visit www.globalindustrial.com for customer service.
STARTING THE ENGINE To start the generator, perform the following steps: Unplug all electrical devices from the generator during ignition. Otherwise it will be difficult for the engine to start. Check that the generator is properly grounded. Check the oil and fuel levels. Turn the fuel valve to the “ON”...
STOPPING THE ENGINE To stop the generator, perform the following steps: • Turn off all electrical devices prior to unplugging them from the generator. Unplugging running devices can cause damage to the generator. • Turn the “ON/OFF” switch to the “OFF” position. •...
MAINTENANCE Follow maintenance schedule intervals, whichever occurs first according to use. NOTE: Adverse conditions will require more frequent service. All required service and adjustments should be performed each season as detailed in the following chart: At Each Use Check engine oil level Every 25 Hours Clean Air Filter** Every 100 Hours or Every Season*...
Turn knob and remove air filter cover. Wash in soapy water. Squeeze filter dry in clean cloth. DO NOT twist. Clean air filter cover before reinstalling it. Model 716173 Model 716174 3300 Watts 7000 Watts SERVICING SPARK PLUG Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use recommended replacement plugs only.
INSPECT MUFFLER SPARK ARRESTOR Inspect muffler for cracks, corrosion or other damage. Remove spark arrestor, if equipped, inspect for damage or carbon blockage. Replace parts as required. Loosen spark arrestor screen clamp and remove screw. Inspect screen and replace if torn, perforated or otherwise damaged. If screen is not damaged, clean with commercial solvent.
STORAGE DANGER: Fuel and vapors are extremely flammable and explosive. Store fuel in a well ventilated area. Keep away from any sparks and fire. Failure to do so will result in death or serious injury. WARNING: Verify machine has properly cooled before installing cover and storing. Hot surfaces could result in fire.
TROUBLESHOOTING Symptom Cause Solution Start switch is set to "off" Set start switch to "on" Engine will not start Fuel valve is turned to "closed" Turn fuel valve to "open" Choke is set to "Run" Set the choke to "Start" Engine is out of gasoline Add gasoline Engine is filled with contaminated/old...
Need help?
Do you have a question about the 716174 and is the answer not in the manual?