7-INSTALLATION AND ASSEMBLY

REAR PANEL
If maintenance must be performed on a component of the stove, the rear panel can be removed (if the distances from the walls allow it),
otherwise, the maintenance can be performed by removing the side of the stove.
To remove the rear panel, remove the seven rear screws "a" and pull panel "L" away.
The "L" panel can also be removed with the stove installed since its shape corresponds with the smoke outlet pipe. Plate "L1" supports the
flue pipe as it is secured to the stove using the two screws "a". With the stove installed you must only remove plate "L1" if the smoke pipe
must be removed, otherwise remove only plate "L".
L
a
L1
a
a
TERMINAL BLOCK ACCESS PANEL
Make the connections to the terminal block by loosening the two screws "k", grasping bracket "S" for the guide and remove the entire unit
with the terminal block.
Make the connections and reinstall everything.