OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt
Keypad 3035, 3710, 3750 or 3750K with reading contact
3035
3710
Generally
Each pressing of a key is confirmed by a signal (an acoustic signal and a LED flash). A valid code is
followed by a double signal, an invalid code by a triple signal. After an interval of more than 10-seconds,
the already entered part of the code is deleted and the entire sequence has to be re-entered.
Code entering:
a) Operation with parallel code:
(manager mode)
b) Operation with dual codes:
(must be programmed)
Opening:
Locking:
I M P O R T A N T
Wrong try penalty:
Change of code:
(always with open door)
LG 39E Combogard EN
Revise: 1
Datum: 16-02-05
Internet: http://www.lagard.nl
3750
Enter the seven-digit numeric code–or a word with 7 characters
a double signal is followed.
Manager code: 1234567
Six-digit numeric codes or words with six characters.
For opening two valid codes must be entered.
Manager code: 123456 and User ID# 654321
Combogard: Enter the code and (after double signal) turn the
entry clockwise within 3 seconds unto the hold. The lock is open
and the entry is rotated.
Swingbolt: Enter the code and (after double signal) turn the
handle within 3 seconds into the OPEN position.
If the lock is not opened within 3 seconds, it is automatically
locked again.
Combogard: Turn the entry counter-clockwise unto the hold.
The lock is automatically closed and the entry stands straight.
(Check this by trying to turn the entry back again)
Swingbolt: Turn the handle into the CLOSE position.
The lock is automatically locked; check this by trying to turn the
handle into "OPEN" position.
Check the lock to be locked.
After four invalid codes, the entry is blocked for about 5
minutes. During this period, the lock signals at 10-second
intervals. After this time penalty, the entry of every second
invalid code initiates a new 5 minutes delay period.
The key pressing is refused with a triple signal.
The user can change its code anytime.
Enter the code and keep pressed the last number until second
double signal (LED is on), press the "0" and enter the new code
(double signal), enter the new code once more for confirmation
(double signal).
The new code is now valid. If mistakes are made while
changing the code or if an interval occurs of more than 10
seconds, the old code remains valid and the entire sequence
has to be re-entered.
Test the new code several times by open door!
1
Get other manuals https://www.bkmanuals.com
Kantooradres:
Vlijtstraat 40
NL-7005 BN Doetinchem
H.R. te Arnhem nr: 09087869
BTW nr: NL 8038.72.987.B01
Lock 39E
LED
3750K
Postadres:
Postbus 127
NL-7000 AC
Tel: (+31) 314 376 876
Fax: (+31) 314 376 878
Contact of
the audit trail

Advertisement

loading
Need help?

Need help?

Do you have a question about the 3035 and is the answer not in the manual?

Questions and answers

Lynn Stocks
February 5, 2025

We have a Combogard 3035 electronic entry device which is currently locked "open" meaning we can't lock the door it is attached to. There has been a change of staff and the original combination code is unknown. We have the instructions on how to change the code but to do this we need the original code. Is there a master code or anything that can be used to allow us to reset this please?

User image 67a382985d04a
1 comments:
Mr. Anderson
May 14, 2025

No, there is no master code for the La Gard Combogard 3035 electronic entry device to reset the combination code. Resetting requires using a RESET-BOX connected to the lock.

This answer is automatically generated

Summary of Contents for La Gard 3035

  • Page 1 Tel: (+31) 314 376 876 E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878 OPERATING INSTRUCTIONS LG 39E Multi User Combogard /Swingbolt Keypad 3035, 3710, 3750 or 3750K with reading contact Lock 39E Contact of the audit trail 3750 3750K...
  • Page 2 The codes are stored in the lock also without power supply. 3710, 3750 and 3750K: Battery compartment is in the bottom of the entry. 3035: Open battery box (inside door) and insert new batteries. If the batteries have not been changed in time and the tension does not suffice to cancel the lock‘s blocking feature, a new 9V DURACELL...
  • Page 3 Kantooradres: Postadres: Vlijtstraat 40 Postbus 127 LA GARD Locks BV NL-7005 BN Doetinchem NL-7000 AC H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876 E-mail: info@lagard.nl Internet: http://www.lagard.nl BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878 Manual programming...

This manual is also suitable for:

371037503750k