4200 is a new part
number replacing the
3765-2
Suggested Keypads
3715 LGBASIC II
3000 Round Entry
FEATURES
MANAGER CODE (Factory set to 1-2-3-4-5-6)
• Add/Remove User
• Enable/Disable User
USER CODE
• Open Lock
• Change Code
WRONG TRY PENALTY
• Four (4) consecutive invalid codes initiates five minute delay
period.
LOW BATTERY WARNING
• Repeated audio and visual signal (LED flashing and repeated
beeping) during opening indicates battery low.
AUDIO AND VISUAL SIGNAL
• Double signal (LED flashes and unit beeps) indicates entry is
valid or accepted.
• Triple signal indicates invalid or not accepted.
OPENING THE LOCK
1 Enter valid six (6) digit code.
2 The lock will signal a valid code entry with a double signal.
3 Within four (4) seconds, turn handle to the open position.
4 Pull door open.
• Invalid Code Entry - Lock will signal three (3) times.
• Security Considerations - On safes using more than one
lock the swingbolt must lock first.
12-219v2
© copyright 2005
3765-2 / 4200 Dual-Handed Swingbolt Lock Instructions
MANAGER PROGRAMMING
3900 LGACCESS
Handle
Input
(Manager)
9-29-05
CHANGING YOUR CODE
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter "zero" six times.
2 Enter your existing six (6) digit code one time.
3 Enter your NEW six (6) digit code two times.
4 If a mistake is made wait thirty (30) seconds and repeat
steps 1 - 3.
5 Test lock operation several times before closing the door.
• Valid Code Entry - Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
ADD USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
2 PRESS 1. Lock signals twice.
3 Enter user code twice. The lock signals twice after each
valid entry.
4 If a mistake is made wait thirty (30) seconds and repeat
steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DISABLE USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
2 PRESS 2. Lock signals once.
3 User is temporarily disabled.
4 If a mistake is made wait thirty (30) seconds and repeat
steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
REINSTATE USER
ALWAYS PERFORM THIS OPERATION WITH THE DOOR
OPEN
1 Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
2 PRESS 1. Lock signals once.
3 User is reinstated.
4 If a mistake is made wait thirty (30) seconds and repeat
steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
LA GARD INC