USER OPERATING INSTRUCTIONS
Please see Manager Instructions for
additional features that may be
activated on your unit.

OPENING THE LOCK

1). Enter valid six (6) digit code.
2). The lock will indicate a valid code entry with a double signal.
3). Within four (4) seconds, turn keypad to open position. (Clock-wise)
4). Pull door open.
• Invalid Code Entry - Lock will signal three (3) times.

WRONG TRY PENALTY

• Entry of four (4) consecutive invalid codes starts a 5-minute delay period.
- LED flashes red at ten (10) second intervals.
• At the end of the delay period, two more consecutive invalid codes will restart
an additional 5-minute delay period.
Entry will not respond to a single keystroke during delay period.

CHANGING YOUR CODE

ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1). Enter "zero" six times.
2). Enter your existing six (6) digit code one time.
3). Enter your NEW six (6) digit code two times.
4). If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Note: Test lock operation several times before closing the door.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
© copyright 2006
3035 Electronic Entry Device
(P/N) 12-202 rev 4 • 7/07

FEATURES

USER CODE

• Open Lock
• Change Code
WRONG TRY PENALTY
• Four (4) consecutive invalid codes
initiates five-minute delay period.

LOW BATTERY WARNING

• Repeated audio and visual signal (LED
flashing and repeated beeping) during
opening indicates battery low.

AUDIO AND VISUAL SIGNAL

• Double signal (LED flashes and unit
beeps) indicates entry is valid
or accepted.
• Triple signal indicates invalid or
not accepted.
LA GARD - A Member of The Kaba Group
Page 1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COMBOGARD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for La Gard COMBOGARD

  • Page 1 • Valid Code Entry - Double signal after valid six (6) digit code is entered. • Invalid Code Entry - Triple signal and old code is still valid. © copyright 2006 (P/N) 12-202 rev 4 • 7/07 LA GARD - A Member of The Kaba Group Page 1 of 2...
  • Page 2 • Uses either one (1) 9-Volt Alkaline Battery or six (6) “C” cell batteries. LA GARD recommends the use of Duracell™ or Eveready™ Alkaline batteries. LA GARD recommends the replacement of batteries at least once annually. • If internal battery is depleted and will not allow lock to open, hold a new 9-volt alkaline battery on the contact points (large battery terminal to large keypad contact, small to small) located on the front of the keypad.

This manual is also suitable for:

3035

Table of Contents