8300100104
VBH0310CTRLS

3.2 Nominal data

Motor
E11233-60
Phase
3~
Nominal voltage / VAC
400
Nominal voltage
380 .. 480
range / VAC
Frequency / Hz
50/60
Method of obtaining
ml
data
Status
prelim.
Speed (rpm) / min
-1
4560
Power consumption / W
2750
Current draw / A
4.3
Min. ambient
-40
temperature / °C
Max. ambient
40
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
01 Overall efficiency η
/ %
es
02 Measurement category
03 Efficiency category
04 Efficiency grade N
05 Variable speed drive
06 Year of manufacture
07 Manufacturer
08 Type
09 Power consumption P
/ kW 2.75
ed
09 Air flow q
/ m³/h
v
09 Pressure increase total p
/
fs
Pa
10 Speed (rpm) n / min
-1
11 Specific ratio
*
12 Recycling/disposal
13 Maintenance
14 Additional components
*
Specific ratio = 1 + p
/ 100 000 Pa
fs
Data obtained at optimum efficiency level. The efficiency values displayed for achieving
conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air
duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If
other air conduction geometries are used on the installation side, the ebm-papst evaluation
loses its validity/the conformity must be confirmed again. The product does not fall within
the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)
(motors completely integrated into a product).
Item no. 1170000606 · ENU · Change 0 · Approved 2021-12-16 · Page 5 / 16
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
Actual
Req. 2015
70.9
56.1
A
Static
76.8
62
Yes
The year of manufacture is specified on the
product's rating label.
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen
8300100104
4370
1533
4560
1.02
Information on recycling and disposal is
provided in the operating instructions.
Information on installation, operation and
maintenance is provided in the operating
instructions.
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

3.4 Technical description

Size
310 mm
Motor size
112
Rotor surface
Painted black
Electronics housing
Die-cast aluminum
material
Impeller material
PP plastic
Support plate material
Sheet steel, galvanized
Support bracket
Steel, painted black
material
Inlet nozzle material
ABS plastic
Number of blades
5
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP55
Insulation class
"F"
Moisture (F) /
H1
Environmental (H)
protection class
Ambient temperature
Occasional start-up at temperatures
note
between -40°C and -25°C is permitted.
For continuous operation at ambient
temperatures below -25°C (such as
refrigeration applications), use must be
made of a fan design with special low-
temperature bearings.
Installation position
See legend on product drawing
Condensation
On rotor side
drainage holes
Mode
S1
Motor bearing
Ball bearing
Technical features
- Operation and alarm display with LED
- External 15-50 VDC input
(parameterization)
- Alarm relay
- Integrated PI controller
- Configurable inputs/outputs (I/O)
- MODBUS V6.3
- Motor current limitation
- RS-485 MODBUS-RTU
- Soft start
- Voltage output 3.3-24 VDC, Pmax =
800 mW
- Control interface with SELV potential
safely disconnected from the mains
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection
- Vibration sensor
Touch current
<= 3.5 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Electrical hookup
Terminal box
Motor protection
Electronic motor protection

Hide quick links: