Nominal Data; Data According To Commission Regulation (Eu) 327/2011; Technical Description - ebm-papst R3G280-AF42-62 Operating Instructions Manual

Table of Contents

Advertisement

R3G280-AF42-62

3.2 Nominal data

Motor
Phase
Nominal voltage / VAC
Frequency / Hz
Method of obtaining
data
Speed (rpm) / min
-1
Power consumption / W
Current draw / A
Min. ambient
temperature / °C
Max. ambient
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
01 Overall efficiency η
02 Measurement category
03 Efficiency category
04 Efficiency grade N
05 Variable speed drive
06 Year of manufacture
07 Manufacturer
08 Type
09 Power consumption P
09 Air flow q
/ m³/h
v
09 Pressure increase total p
Pa
10 Speed (rpm) n / min
11 Specific ratio
*
12 Recycling/disposal
13 Maintenance
14 Additional components
*
Specific ratio = 1 + p
/ 100 000 Pa
fs
Data obtained at optimum efficiency level. The efficiency values displayed for achieving
conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air
duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If
other air conduction geometries are used on the installation side, the ebm-papst evaluation
loses its validity/the conformity must be confirmed again. The product does not fall within
the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)
(motors completely integrated into a product).
Item no. 51834-5-9970 · ENU · Change 273261 · Approved 2022-11-21 · Page 6 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Arrow.com.
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Operating instructions
M3G084-DF
1~
230
50/60
ml
2550
415
1.8
-25
45
Actual
Req. 2015
/ %
50.5
47.5
es
A
Static
65
62
Yes
The year of manufacture is specified on the
product's rating label.
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen
R3G280-AF42-62
/ kW 0.41
ed
1595
/
424
fs
-1
2475
1.00
Information on recycling and disposal is
provided in the operating instructions.
Information on installation, operation and
maintenance is provided in the operating
instructions.
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

3.4 Technical description

Weight
5.1 kg
Size
280 mm
Motor size
84
Rotor surface
Painted black
Electronics housing
Die-cast aluminum
material
Impeller material
Sheet steel, galvanized
Number of blades
11
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"B"
Moisture (F) /
H1
Environmental (H)
protection class
Installation position
Shaft horizontal or rotor on top; rotor on
bottom on request
Condensation
None
drainage holes
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 10 mA
- Alarm relay
- Motor current limitation
- PFC, active
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection
Touch current
<= 3.5 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I; If a protective earth is connected by
assignment
the customer
This component for installation may
have several local protection classes.
This information relates to this
component's basic design.
The final protection class is based on
the component's intended installation and
connection.
Conformity with
EN 61800-5-1; CE
standards
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
; Use the device in accordance with its degree of protection.