Removing The Backplane - Dell KGR3H Installation And Service Manual

Table of Contents

Advertisement

Figure 33. 8 x 2.5-inch drive backplane
1. BP_PWR_1 (backplane power and signal cable to PIB)
Figure 34. 10 x 2.5-inch NVMe drive backplane
1. DST_PA3 (PCIe/NVMe connector)
3. DST_PB2 (PCIe/NVMe connector)
5. DST_SA1 (PERC to backplane)
7. DST_PA1 (PCIe/NVMe connector)

Removing the backplane

Prerequisites
CAUTION:
To prevent damage to the drives and backplane, remove the drives from the system before removing
the backplane.
CAUTION:
Note the number of each drive and temporarily label them before you remove the drive so that you
can reinstall them in the same location.
NOTE:
The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the air
shroud.
4.
Remove the backplane cover
5. Remove all the drives.
6. Disconnect the VGA cable from the system board.
NOTE:
Observe the routing of the cable as you remove it from the system.
7. If installed, disconnect the optical drive signal and power cables from the system.
8. Disconnect the drive backplane cables from the connectors on the system board.
Steps
1. Press the blue release tabs to disengage the drive backplane from the hooks on the system.
2. Lift the drive backplane out of the system.
NOTE:
To avoid damaging the backplane, ensure that you move the control panel cables from the cable routing clips
before removing the backplane.
Safety
instructions.
Before working inside your
2. DST_SA2 (backplane to front PERC)
4. DST_PA2 (PCIe/NVMe connector)
6. BP_PWR_1 (backplane power and signal cable to PIB)
8. DST_PB1 (PCIe/NVMe connector)
system.
Installing and removing system components
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc poweredge r650xs

Table of Contents