Removing The Back Panel - Maytag MED6400TQ0 Manual

Hide thumbs Also See for MED6400TQ0:
Table of Contents

Advertisement

TECH SHEET - DO NOT DISCARD
Cycle Selector
Switch
Locking
Tabs
Figure 16. Gently apply pressure to
locking tabs to release the user interface
assembly.
7. Locking tabs located at the bottom of
the console insert panel secure the
user interface assembly to the console
insert panel. Using a flat-blade
screwdriver, gently apply pressure to
the locking tabs to release the user
interface assembly. See figure 16.
Reinstalling the Electronic
Assemblies
Refer to preceding removal sections and
replace in reverse order.
NOTE: When replacing the cycle selector
switch, make sure that the shaft is positioned
through the center of the shaft seal that is
captive between the decorative overlay and
the console panel insert.
NOTE: When reconnecting wire
connections, be sure to route the user
interface wires beneath the retainer clips on
the user interface back cover.
12/06

REMOVING THE BACK PANEL

1. Unplug dryer or disconnect power.
2. Remove the cover plate screw and cover
plate. See figure 17.
3. Remove the nine rear screws from the
back panel, then remove panel.
Cover Plate Screw
User Interface
Assembly
Figure 17. Remove screws.
FOR SERVICE TECHNICIAN'S USE ONLY
Cover Plate
4,669,200
4,700,495
4,754,556
4,840,285
4,865,366
4,899,464
4,908,959
SOFTWARE COPYRIGHTED.
MANUFACTURED UNDER ONE OR MORE
OF THE FOLLOWING U.S. PATENTS:
4,989,347
6,446,357
5,066,050
6,597,144
5,560,120
6,604,298
5,809,828
6,685,241
6,020,698
6,732,447
6,047,486
6,784,673
6,199,300
6,819,255
PART NO. W10114194A
PAGE 12
D314,261
D314,262
D457,991
D457,992
D495,453

Advertisement

Table of Contents
loading

This manual is also suitable for:

Med6400tb0

Table of Contents