Revision History Date Doc Version Description May 24, 2023 V 1.0 Initial version 1. Add staff lanyard accessory; 2. Add multi-device stitching feature; 3. Add installation height detection feature; 4. Add DHCP feature; Aug. 10, 2023 V 1.1 5. Display HTTP/MQTT connection status and support data re-transmission feature;...
The advanced ToF technology combined with an AI algorithm enables the sensor to handle complex scenes and distinguish non-human objects with up to 99.8% accuracy. With easy installation, VS133-P is ideal for entrances or corridors in retail stores, malls, offices, subways, and other locations.
Powered by a PoE Injector 4. Access the Sensor VS133-P sensor provides user-friendly web GUI for configuration and users can access it via Ethernet port. The recommended browsers are Chrome and Microsoft Edge. The default IP of Ethernet port is 192.168.5.220 (can be found on the device label).
Page 8
Enter an IP address that in the same segment with sensor ( e.g. 192.168.5.61, but please note that this IP address shall not conflict with the IP address on the existing network); Step 3: Open the Browser and type 192.168.5.220 to access the web GUI. Step 4: Select the language.
Note: When working mode is Node mode, the device will not show people counting data. 5.2 Rule VS133-P supports 3 working modes: Standalone Mode: works as a standalone device to count people. Master Mode: works as a master device to receive live view and tracks from other node devices.
Node Mode: works as a node device to forward live view and tracks to the master device. 5.2.1 Basic Counting Settings Draw Detection Lines Users can draw detection lines to record the people count values which indicate the number of people enter or exit.
Page 12
2) Ensure that the detected target can pass through the detection line completely. It’s recommended that the detection line is perpendicular to the In/Out direction and on the center of the detection area without other objects around. 3) A redundant identification area needed to be left on both sides of the detection line for the target.
Page 13
is 1.6 m to 1.8 m, the Max. and Min. Target Height should be configured as 1.835 m and 1.565 m respectively. Counting Strategy Parameters Description When enabled, it allows to draw an area for every line and the device will count the In and Out values only when people passed this area.
Parameters Description Trigger Report Report the people counting data immediately when the in/out value changes. Periodic Report Report the people counting data periodically. Set the period of reporting periodic report. Period Range: 1-1080 mins, default: 10 mins 5.2.2 Multi-Device Stitching Multi-device stitching is mainly used to monitor a larger detection area than just the area covered by a single device.
Page 15
Device Positioning Device positioning is done via X&Y coordinates. For example, the installation direction of the master device is shown as below. When the master device’s coordinate is (0, 0), the coordinates of the node devices are all positive values. Add Node Devices Step 1: Go to the master device web GUI, then click BindNode on Multi-Device List.
Page 16
Step 4: Select the node device on the Mult-Device List, click Adjust Relative Position. Drag the live view of node device to adjust the location and angle, and the relative position parameters will change automatically as your operations. Besides, users can also adjust the size of this live view.
Page 17
Step 6: When all settings are completed, users can draw detection lines and even U-turn areas on the new stitching live view the same as standalone mode devices. Step 7: Click Unbind to disconnect the node device if necessary. Node Mode...
Device the list of the master device. 5.3 Communication VS133-P provides a Ethernet port for wired access. Besides, users can get the people counting data or configure the device via CGI. For CGI document, please contact Milesight IoT support: iot.support@milesight.com.
Page 19
Parameters Description IP Assignment Manual or Automatic (DHCP) is optional. Set the IPv4 address of the Ethernet port, the default IP is IP Address 192.168.5.220. Subnet Netmask Set the Netmask for the Ethernet port. Default Gateway Set the gateway for the Ethernet port's IPv4 address. Primary DNS Server Set the primary IPv4 DNS server.
Page 20
Note: When working mode is the Node mode, the device will not support HTTP/MQTT settings. Parameters Description Protocol HTTP (post) or MQTT is optional. Show connection status from device to HTTP server or MQTT broker. Status Note: When it is being disconnected, the device will store up to 100,000 pieces of data and re-transmit them when the connection is back.
5.4 Report VS133-P supports to generate visual line chart or bar chart to display the people traffic and supports to export the report. Before using this feature, ensure that the device time is correct on System page. Note: When working mode is Node mode, the device will not generate this report.
management. 5.5.2 User Parameters Description Click the admin on the user list, then you can click Modify to change the login Modify password of this device.
Click to type administrator password, then set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly. Security Question 5.5.3 Time Configuration...
Set the interval to sync time with NTP server. Setting Time Set the device time manually. Synchronize with Synchronize the time with your computer. computer time 5.5.4 Remote Management Users can connect the device to the Milesight DeviceHub management platform on this page so...
DeviceHub as to manage the device centrally and remotely. For more details, please refer to User Guide Before connecting, ensure the device has connected to network via Ethernet port and Internet connection is seamless. Parameters Description Status Show the connection status between the device and the DeviceHub. Server Address IP address or domain of the DeviceHub management server.
IR devices. When using Multi-Device Stitching, please avoid using Frequency the same mode with other node devices. Adjustment Note: if there is only one option, please contact Milesight IoT support: iot.support@milesight.com Recovery device basic configuration: keep the IP settings and user information when resetting. Reset Recovery device to factory settings: reset device to factory default, which needs to verify admin password.
Maximum pedestrian height Example 1.8 m Minimum pedestrian height Example 1.7 m α ToF horizontal field of view angle 98° β ToF vertical field of view angle 80° Length of detection range Width of detection range 6.1 Installation Height The maximum installation height is 3.5 m and the minimum installation height is h +d+Δd.
(Note: if the alarm I/O of VS133-P is going to be used, please connect a multi-interface cable to the device)
Page 29
Step 5: Remove the cover on the device, and then connect all required wires and pass them through the inside of pole. (Note: if the alarm I/O of VS133-P is going to be used, please connect a multi-interface cable to the device)
Page 30
Note: Tilt installation should be avoided. Ensure that the front of the device and the ground plane are paralleled. Avoid installing the device against the wall and ensure that the device keeps away from the wall at least 30 cm on the short side and 50 cm on the long side. Ensure that there are no other objects blocking the ToF light within a 30 cm radius of the ...
Handheld or cart-carrying a humanoid doll with sufficient height to pass by: The doll will be mistakenly detected as people because it is human-like in depth map. 7. Communication Protocol VS133-P will post the people counting data in json format to HTTP URL or MQTT broker. Periodic Report "event":"People Counting", "report_type": "period", "device_info":{...
Page 33
"device_name":"People Counter", "device_sn":"369362028335", "device_mac":"00:16:28:FA:8E:68", "ip_address":"192.168.0.99" "cus_device_id":"123468773", //Customized device ID "cus_site_id":"asdfasf1231231" //Customized site ID "running_time": 1564648484648 //unit: s "time_info":{ “time_zone":"UTC-11:00 Samoa Standard Time (SST)", "enable_dst":false, //DST time is enabled or disabled "dst_status":false, //Whether DST takes effect "time":"2022-12-20T18:15:52+03:00", //Triggering time "trigger_data":[ "line":1, "in":1, //One person in "out":0,...