Page 1
Ultra ToF People Counter VS135-HL User Guide...
Page 2
Safety Precautions Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at the ToF sensor too close and directly.
Page 3
Revision History Date Doc Version Description March 23, 2024 V 1.0 Initial version...
intelligent detection. Support video validation function to help customers verify statistical accuracy. High compatibility of data transmission(HTTP/MQTT). Support local data storage and data retransmission to collect data securely. Quick and easy management with Milesight DeviceHub. ...
Wi-Fi button for more than 3 Wi-Fi On: Blue light on. seconds. Wi-Fi Off: Green light on. Press and hold the reset Reset to Green light blinks until the reset process is button for more than 10 Factory Default completed. seconds.
Page 8
the first time (three questions can be skipped by refreshing webpage). After configuration, log in with username (admin) and custom password. Note: Password must be 8 to 16 characters long, which contains at least two kinds or more in combination with numbers, lowercase letters, uppercase letters and special characters. You can click the “forgot password”...
5. Operation Guide 5.1 Dashboard After logging on to the device web GUI successfully, user is allowed to view live video as following. Parameters Description Hide Capacity: Hide the total count data capacity; Staff Excluded: Exclude staff data from statistical data; Children Excluded: Exclude children data from statistical data.
Click to output a 5s high level signal from alarm out interface. Digital Output Alarm Output: dry contact, output=two contacts closure Click to edit the preview layout. Step 1: Select video stream preview, static image preview or no image preview as needed. Step 2: Click to show tracking lines, detection lines, U-turn areas and detection regions as needed.
Page 11
Note: The arrow direction of the detection line depends on your drawing direction. If users need to flip the line, select the line which need to be flipped and click Flip Arrow Direction. And users can click Flip All to flip all detection lines. Ensure that the detected target can pass through the detection line completely.
Page 12
Parameters Description Set the device installation height. Click Detect to detect the current installation height automatically. Note: Installation Height 1) Ensure that there is no object directly below the device avoiding interfering the height detection. 2) The automatic detection of the installation height is not supported...
Page 13
with dark floor/carpet (black, grey, etc.) Max. Target Set the maximum target height, then the device will ignore the objects Height higher than this setting value. Set the minimum target height, then the device will ignore the object Min. Target Height shorter than this setting value.
Step 3: The configuration is displayed in the list after the configuration is complete. You can redraw the areas by clicking the redraw button in the list. Click the edit button to modify the advanced settings of the areas or click delete button to delete the areas separately.
Page 15
VS135-HL supports Wi-Fi for web access and Wi-Fi HaLow for data transmission. WLAN Description .Parameters Enable or disable Wi-Fi feature. If disabled, users can use button to Enable WLAN enable it. The unique name for this device Wi-Fi access point, defined as Wi-Fi SSID People Counter_xxxxxx (can be found on the device label).
5.3.2 Recipient VS135 supports to add data receivers (supports HTTP(s)/MQTT(s)). The device will proactively push data to the receivers according to the configured reporting scheme. Note: Up to 8 receivers can be added. Parameters Description Recipient Name Show the recipient name. URL/Host Show the URL/host of HTTP(s) server or MQTT broker.
Page 17
Parameters Description Recipient Name Customize the recipient name. Protocol HTTP(s) or MQTT is optional. Status Show connection status from device to HTTP server or MQTT broker. HTTP(s) Connection Test Click Test to send test message to URL to check connectivity. The device will post the people counting data in json format to this URL.
Periodic Report Select the periodic report of “On the Dot” or “From Now On”. Periodic Report On the Dot: The device will report at the top of each hour. For example, Scheme When the interval is set to 1 hour, it will report at 0:00, 1:00, 2:00 and so on; when the interval is set to 10 minutes, it will report at 0:10, 0:20, 0:30, and so on.
Parameters Description Select the event which you want to query the report. Line crossing Event counting, region people counting, dwell time detection and heat map are optional. Time Unit Select the unit to generate the graph or export the data. Time Range Select the time range to generate the graph.
Page 20
up a video task of recording. Note: Only one video task can be performed at a time, please delete the previous task before creating a new one. Detection rules and ToF frequency parameters cannot be modified during the recording ...
Enable/Disable detection lines in the recording footage. Enable/Disable u-turn area in the recording footage. Enable/Disable detection region in the recording footage. Playback Button Enable/Disable tracking line in the recording footage. Rewind/Pause/Play/Forward(supports switching between 0.5x, 1x, 2x, and 4x playback speed). Start time and end time of the recording.
5.6.2 User Parameters Description You can change the login password of this device. Click to set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly.
Setting Time Set the device time manually. 5.6.4 Remote Management Users can connect the device to the Milesight DeviceHub management platform on this page so DeviceHub as to manage the device centrally and remotely. For more details, please refer to...
Frequency the same mode with other node devices. Adjustment Note: If there is only one option, please contact Milesight IoT support: iot.support@milesight.com Adjust the ToF light mode as Always On or Auto. When using Auto mode, the Lighting device will turn off the ToF light when radar detects no person for some times to save the power.
6. Installation Instruction Parameter definition: Parameters Explanation Value Standard Version: ≤3.5 m Installation height High Ceiling Mount: ≤6.5 m Standard Version: 0.5 m Minimum detection distance of VS135 High Ceiling Mount: 2 m Δd Distance measurement error of VS135 0.035 m Maximum pedestrian height Example 1.8 m Minimum pedestrian height...
Page 27
For example, if the Minimum height of pedestrians is 1.7 m, the detection area corresponding to each installation height is as follows: Standard Version: Installation Height (m) Monitored Area (m) Detection Area(m) 5.75 × 4.20 1.84 × 1.34 5.98 × 4.36 2.07 ×...
5.66 x 4.06 3.70x 2.65 5.89 x 4.22 3.93 x 2.82 6.12 x 4.39 4.16 x 2.98 6.35 x 4.56 4.39 x 3.15 6.35 x 4.72 4.62 x 3.31 6.81 x 4.89 4.85 x 3.48 7.04 x 5.05 5.08 x 3.65 7.27 x 5.22 5.31 x 3.81 7.51 x 5.38...
6.4 Installation Ceiling Mount Installation condition: ceiling thickness > 30mm. Step 1: Take down the side covers. Step 2: Fix wall plugs into ceiling holes. Step 3: Remove rubber plugs on the rubber sleeve, connect all required wires. Note: Remove the rubber sleeve if waterproof is not required for easy installation. ...
Page 30
Step 5: Restore side covers. Ceiling/Lintel Mount (with Optional VB01 Multifunctional Bracket) Step 1: Fix the pole to the device with the hole on the device. Step 2: Adjust the length of the pole, then adjust the direction of 3-axis ball and tighten it with the handle. Step 3: Determine the mounting location and drill 3 holes, fix the wall plugs into the mounting holes, then fix the bracket base to the wall plugs via mounting screws.
Page 31
Lintel Mount Installation Note: Ensure that the ToF sensor is facing down and the tilt angle from the ground is no greater than 15° for the standard version, and no greater than 10° for the high ceiling mount version. Avoid direct Infrared LED light in the detection area.
from the door with a distance of at least 40cm. 6.5 Factors Affecting Accuracy Wearing a fisherman's hat or carrying a cardboard box on the shoulder: The target will not be recognized because it will become unlike a human in depth map. Handheld or cart-carrying a humanoid doll with sufficient height to pass by: The doll will be ...
Need help?