  • Page 1 AI Stereo Vision People Counter VS125 User Guide...
  • Page 2: Safety Precautions

    Use a soft, dry cloth to clean the lens of the device.  Declaration of Conformity VS125 is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS. Copyright © 2011-2024 Milesight. All rights reserved.
  • Page 3: Revision History

    Revision History Date Doc Version Description Jul. 17, 2024 V1.0 Initial version...
  • Page 4: Table Of Contents

    Contents 1. Product Introduction ......................... 5 1.1 Overview ...........................5 1.2 Key Features ..........................5 2. Hardware Introduction ........................6 2.1 Packing List ..........................6 2.2 Hardware Overview ......................... 2 2.3 Button Descriptions .........................2 2.4 Dimensions (mm) ........................2 2.5 SIM Card Installation (Cellular Version Only) ................ 3 3.
  • Page 5: Product Introduction

    1. Product Introduction 1.1 Overview VS125 is a professional people counting sensor that is based on deep learning AI and Binocular Stereo Vision technology. This sensor possesses an impressive accuracy of up to 99.8% in people counting, and it delivers exceptional performance even in low light environment and total darkness.
  • Page 6: Hardware Introduction

    High compatibility of data transmission with HTTP(s)/MQTT(s) protocol and API, supports  customized push content and push method 2. Hardware Introduction 2.1 Packing List 1 × VS125 Device 4 × Ceiling Mounting Kits 1 × Multi-interface Cable 1 × Warranty Card 1 × Quick Guide 1 ×...
  • Page 7: Hardware Overview

    2.2 Hardware Overview Cellular Version:  PoE Version:  2.3 Button Descriptions Function Action LED Indication Press and hold the power Turn On/Off: Blue light blinks for 3 seconds. Turn On/Off button for more than 3 Wi-Fi On: Blue light on. Wi-Fi seconds.
  • Page 8: Sim Card Installation (Cellular Version Only)

    2.5 SIM Card Installation (Cellular Version Only) Step 1: Remove the cover plate. Step 2: Use the SIM-eject tool to pop open the SIM tray. Step 3: Place the Nano SIM card into the sim card slot and insert it back to device.
  • Page 9: Power Supply

    Note:Ensure the length of the Ethernet Cable crystal head is less than 40mm. 4. Access the Sensor VS125 provides user-friendly web GUI for configuration access via Wi-Fi or Ethernet port. Users need to customize the password when using the device for the first time. The default settings...
  • Page 10 Step 1: Wireless Method: Enable the Wireless Network Connection on your computer, search for  corresponding for Wi-Fi SSID to connect it, then type 192.168.1.1 to access the web GUI. Wired Method (PoE Version Only): Connect the device to computer via Ethernet port, ...
  • Page 11 Parameters Description Select video stream preview, static image preview or no image preview as Scene Preview needed. Image Type Select Monochrome or Pseudo-color image type. Click to output high level signal from alarm out interface when Manual DO event is enabled. Resolution Low: Display blurred images, but still allow viewing of scenes and moving people...
  • Page 12: Operation Guide

    5. Operation Guide 5.1 Dashboard After logging on to the device web GUI successfully, user is allowed to view live video as following.
  • Page 13: Rule

    Parameters Description Hide Capacity: Hide the total count data capacity; Children Excluded: Exclude children data from statistical data. Reset Count Clear all accumulated entrance and exit people counting values. Click to show detection lines, U-turn areas, detection regions and tracking lines as needed.
  • Page 14 Draw U-turn Area VS125 supports the U-turn filtering function, filtering out the people who are actually not in / out of the entrance, to avoid repeated counting. Users can draw an area for every line and the device...
  • Page 15 Disable U-turn filtering: Enable U-turn filtering: Step 1: Enable U-turn Filtering. Users can click to edit U-turn areas for existed detection line on the live view. Step 2: Left-click to start drawing and drag the mouse to draw an edge. Then left-click again to continue drawing a different direction edge.
  • Page 16 Draw Monitoring Region VS125 supports monitoring the number and the dwell time of people in the region, providing more valuable analysis data. Step 1: Enable Region Monitoring. Click +Add to add the region monitoring on the live view. Up to 4 regions are supported with maximum 10 segments each.
  • Page 17 Step 3: The configuration is displayed in the list after the configuration is complete. You can redraw the areas by clicking the redraw button in the list. Click the edit button to modify the advanced settings of the areas or click delete button to delete the areas separately. Rule Configuration Users can set the rules to ensure accurate counting.
  • Page 18: Communication

    Enable to periodically reset cumulative count on schedule. Reset Cumulative Cumulative Count includes: Count on Schedule Total In/Out counting of each detection line. Max./Avg. Dwell Time of each detection region. 5.3 Communication 5.3.1 Network Configuration VS125 supports variety of ways for data transmission. Cellular (Cellular Version Only)
  • Page 19 Parameters Description Display the connection status of the network, including Cellular Cellular Status “connect” and “disconnect”. You can also click “Detail” button to view the cellular status. Enter the Access Point Name for cellular dial-up connection provided by local ISP. The max length is 31 characters. Enter the username for cellular dial-up connection provided Username by local ISP.
  • Page 20 SIM Card Error  PN Error  PIN Required  PUK Required  No Signal  Ready  Down SIM  Model Show the model name of the cellular module Version Show the version of the cellular module. Signal Level Show the current signal strength of the network.
  • Page 21 Parameters Description TCP/IP IP Assignment Manual or Automatic (DHCP) is optional. Set the IPv4 address of the Ethernet port, the default IP is IP Address 192.168.5.220. Test Click to test if the IP is conflicting. Subnet Mask Set the Netmask for the Ethernet port. Default Gateway Set the gateway for the Ethernet port's IPv4 address.
  • Page 22 Parameters Description Authentication Type It’s fixed as MD5-Challenge. Enable Enable or disable 802.1x authentication. EAPOL Protocol Version 802.1x-2001 or 802.1x-2004 is optional. Username Set the username for 802.1x authentication. Password Set the password for 802.1x authentication. Confirm Password Enter the password again. WLAN...
  • Page 23 Description Parameters Enable or disable Wi-Fi feature. If disabled, users can use button to Enable WLAN enable it. The unique name for this device Wi-Fi access point, defined as Wi-Fi SSID People Counter_xxxxxx (can be found on the device label). Configure WLAN IP address for web access, the default IP address WLAN IP Address is 192.168.1.1.
  • Page 24: Recipient & Api

    5.3.2 Recipient & API Recipient VS125 supports to add data receivers (supports HTTP(s)/MQTT(s)). The device will proactively push data to the receivers according to the configured reporting scheme. Besides, users can get the people counting data or configure the device via CGI. For CGI document, please contact Milesight IoT support: iot.support@milesight.com.
  • Page 25 Parameters Description Recipient Name Customize the recipient name. Report Protocol HTTP(s) or MQTT is optional. HTTP(s) The device will post the people counting data in json format to this URL. Connection Test Click Test to send test message to URL to check connectivity. Username The username used for authentication.
  • Page 26 Customize Report Content MQTT API (Cellular Version Only) VS125 provides MQTT API to support to receive downlink commands from MQTT broker to get people counting data and achieve the configuration. For API document, please contact Milesight IoT support: iot.support@milesight.com.
  • Page 27 Parameters Description Status Show connection status between device and MQTT broker. Host MQTT address to receive data. Port MQTT port to receive data. Topic Topic name used for publishing. Client ID is the unique identity of the client to the server. Client ID It must be unique when all clients are connected to the same server, and it is the key to handle messages at QoS 1 and 2.
  • Page 28: Report

    Export the historical traffic data as CSV file according to the selected time unit. The device can store up to one million data records to CSV file. 5.5 Image VS125 has great lighting adaptability that allows it to work well in low light or even complete...
  • Page 29: System

    dark environments.It supports day and night mode switching based on the no-photosensitive scheme. Parameters Description Set image mode. Auto, Day, Night and Schedule are optional. Day: black and white mode; Day/Night Mode Night: infrared based black and white mode; Switch Auto: automatic switch day and night according to image brightness;...
  • Page 30: User

    5.6.2 User Parameters Description You can change the login password of this device.
  • Page 31 Click to set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly. Click to add a viewer, who will only have access to the "Dashboard" and "Report"...
  • Page 32: Time Configuration

    Synchronize the time with your computer. computer time 5.6.4 Remote Management Milesight provides remote management service for this device via Milesight DeviceHub platform or Milesight Development Platform. Before connecting, do ensure the device is connected to the network and Internet connection is stable.
  • Page 33: System Maintenance

    Parameters Description Remote Management Remote Enable or disable to manage the device through Milesight platforms. Management Platform DeviceHub or IoT Development Platform is optional. Status Show the connection status between the device and the DeviceHub. IoT Development Platform Remote Enable to change the device settings via Milesight Development Management platform.
  • Page 34: Installation Instruction

    Parameters Description Recovery device basic configuration: keep the IP settings and user information when resetting. Reset Recovery device to factory settings: reset device to factory default, which needs to verify admin password. Reboot Restart the device immediately. Click the folder icon and select the upgrading file, then click the Upgrade button to upgrade.
  • Page 35: Covered Detection Area

    5.001 ~ 6 62° 41° 6.1 Covered Detection Area The detection area covered by the device is related to the field of view angle of the device, the installation height and the target height. The length of the detection area is approximately x=2 × tan(α/2) × (H-h-0.05) and the width of the detection area is approximately y=2 ×...
  • Page 36: Installation

    6.2 Installation Ceiling Mount Installation condition: ceiling thickness > 30mm. Step 1: Remove the cover. (If the wires need to be protruded from the side of the device, remove the blocking rubber.) Step 2: Drill 4 holes with a diameter of 4mm according to the hole position of the device screw. (If you need to hide the power cord into the ceiling, drill another wire hole.) Attach the expansion bolts to the hole position in the ceiling.
  • Page 37 Step 5: Fix the cover back to device. Ceiling/Lintel Mount (with Optional VB01 Multifunctional Bracket) Step 1: Fix the pole to the device with the hole on the device. Step 2: Adjust the length of the pole, then adjust the direction of 3-axis ball and tighten it with the handle. Step 3: Determine the mounting location and drill 3 holes, fix the wall plugs into the mounting holes, then fix the bracket base to the wall plugs via mounting screws.
  • Page 38 Lintel Mount  Installation Note: The device is sensitive to ambient light, so it's best to avoid placing it in areas where light  conditions fluctuate significantly. Make sure there are no obstacles within the live view of device.  When the device is installed on the door frame or door, it is recommended to use VB01 or ...
  • Page 39: Factors Affecting Accuracy

     It is indistinguishable when the color of targets and the floor is similar.  7. Communication Protocol VS125 will post the people counting data in json format to HTTP URL or MQTT broker. 7.1 Periodic Report "device_info": "cus_device_id": "123456", "cus_site_id":...
  • Page 40 "in": "line": "line_name": "Line1", "line_uuid": "9a0440de-3188-4f6d-b886-bb20c97bd26b", "male_in": "male_out": "out": "children_in": "children_out": "female_in": "female_out": "in": "line": "line_name": "Line2", "line_uuid": "b138b9a1-ce58-40bd-98f4-c401dfc118c8", "male_in": "male_out": "out": "line_total_data": "capacity_counted": "children_in_counted": "children_out_counted": "female_in_counted": "female_out_counted": "in_counted": "line": "line_name": "Line1", "line_uuid": "9a0440de-3188-4f6d-b886-bb20c97bd26b", "male_in_counted": "male_out_counted": "out_counted":...
  • Page 41 "capacity_counted": "children_in_counted": "children_out_counted": "female_in_counted": "female_out_counted": "in_counted": "line": "line_name": "Line2", "line_uuid": "b138b9a1-ce58-40bd-98f4-c401dfc118c8", "male_in_counted": "male_out_counted": "out_counted": "region_data": "dwell_time_data": "avg_dwell_time": 308367, "children_avg_dwell_time": "children_max_dwell_time": "female_avg_dwell_time": "female_max_dwell_time": 519934, "male_avg_dwell_time": "male_max_dwell_time": 96799, "max_dwell_time": 519934, "region": "region_name": "Region1", "region_uuid": "bd1e6ce2-e113-4ce4-a9b6-0633f7083cac" "avg_dwell_time": "children_avg_dwell_time": "children_max_dwell_time": "female_avg_dwell_time": "female_max_dwell_time":...
  • Page 42 "male_avg_dwell_time": "male_max_dwell_time": "max_dwell_time": "region": "region_name": "Region2", "region_uuid": "f16a2618-f44a-485d-8b4e-d7550a155b8e" "region_count_data": "current_children": "current_female": "current_male": "current_total": "region": "region_name": "Region1", "region_uuid": "bd1e6ce2-e113-4ce4-a9b6-0633f7083cac" "current_children": "current_female": "current_male": "current_total": "region": "region_name": "Region2", "region_uuid": "f16a2618-f44a-485d-8b4e-d7550a155b8e" "time_info": "dst_status": false, "enable_dst": true, "end_time": "2024-05-30T20:21:49+08:00", "start_time": "2024-05-30T20:20:49+08:00", "time_zone": "UTC+8:00 China Standard Time (CT/CST)"...
  • Page 43: Trigger Report-Line Crossing People Counting

    7.2 Trigger Report-Line Crossing People Counting "device_info": "cus_device_id": "123456", "cus_site_id": "789123", "device_mac": "24:E1:24:FA:0C:6C", "device_name": "People Counter", "device_sn": "6384E16179950009", "firmware_version": "V_125.1.0.1", "hardware_version": "V1.0", "ip_address": "192.168.60.183", "running_time": "network_info": //Cellular version only "network_status": "true", //True is connected, False is disconnected "iccid": "89860117838009934120", "imei": "860425047368939", "cell_id": "340db80",...
  • Page 44: Trigger Report-Region People Counting

    "children_in": "children_out": "female_in": "female_out": "in": "line": "line_name": "Line3", "line_uuid": "82ffe54d-0191-484b-a2fc-495628a8f2a1", "male_in": "male_out": "out": "children_in": "children_out": "female_in": "female_out": "in": "line": "line_name": "Line4", "line_uuid": "ebc7b502-08d6-4f61-b704-e02d1938b9e2", "male_in": "male_out": "out": "time_info": "dst_status": false, "enable_dst": true, "time": "2024-05-30T20:11:32+08:00", "time_zone": "UTC+8:00 China Standard Time (CT/CST)" 7.3 Trigger Report-Region People Counting...
  • Page 45 "device_info": "cus_device_id": "123456", "cus_site_id": "789123", "device_mac": "24:E1:24:FA:0C:6C", "device_name": "People Counter", "device_sn": "6384E16179950009", "firmware_version": "V_125.1.0.1", "hardware_version": "V1.0", "ip_address": "192.168.60.183", "running_time": "network_info": //Cellular version only "network_status": "true", ////True is connected, False is disconnected "iccid": "89860117838009934120", "imei": "860425047368939", "cell_id": "340db80", "lac": "5299" "region_trigger_data": "region_count_data": "current_children": "current_female":...
  • Page 46: Trigger Report-Dwell Time Detection

    "dst_status": false, "enable_dst": true, "time": "2024-05-30T20:12:20+08:00", "time_zone": "UTC+8:00 China Standard Time (CT/CST)" 7.4 Trigger Report-Dwell Time Detection "device_info": "cus_device_id": "123456", "cus_site_id": "789123", "device_mac": "24:E1:24:FA:0C:6C", "device_name": "People Counter", "device_sn": "6384E16179950009", "firmware_version": "V_125.1.0.1", "hardware_version": "V1.0", "ip_address": "192.168.60.183", "running_time": "network_info": //Cellular version only "network_status": "true", ////True is connected, False is disconnected "iccid":...
  • Page 47 "people_id": "region": "region_name": "Region1", "region_uuid": "bd1e6ce2-e113-4ce4-a9b6-0633f7083cac", "sex": "male" "time_info": "dst_status": false, "enable_dst": true, "time": "2024-05-30T20:12:20+08:00", "time_zone": "UTC+8:00 China Standard Time (CT/CST)" -END-...