IR Breakbeam
People Counter
Featuring LoRaWAN
®
VS360
User Guide

Advertisement

loading
Need help?

Need help?

Do you have a question about the VS360 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Milesight VS360

  • Page 1 IR Breakbeam People Counter Featuring LoRaWAN ® VS360 User Guide...
  • Page 2: Safety Precautions

    To ensure the security of your device, please change the device password during the initial  configuration. The default password is 123456. The device is not intended to be used as a reference sensor, and Milesight will not hold  responsibility for any damage which may result from inaccurate readings.
  • Page 3: Revision History

    Revision History Date Doc Version Description Aug. 16, 2024 V 1.0 Initial version...
  • Page 4: Table Of Contents

    4.4 Advanced Settings ........................ 12 4.4.1 Threshold Settings ..................... 12 4.4.2 Data Storage ....................... 13 4.4.3 Data Retransmission ....................14 4.4.4 Milesight D2D Settings ....................15 4.5 Maintenance .......................... 17 4.5.1 Backup .........................17 4.5.2 Upgrade ........................17 4.5.3 Reset to Factory Default .....................18 5.
  • Page 5: Product Introduction

    1. Product Introduction 1.1 Overview The VS360 is a people counting sensor that is based on IR Breakbeam technology. Equipped with two devices, the principle is that the target blocks the infrared beam by detecting the area to achieve the purpose of counting, so it is not affected by the ambient temperature and the color of the target clothes, and it has strong adaptability.
  • Page 6: Hardware Overview

    1 × 2 × 4 × ER14505 4 × Wall Screw VS360 Sensor Back Covers Li-SoCl Batteries Mount Kits 2 × 3M Double-sided 1 × 1 × Tapes Quick Start Guide Warranty Card If any of the above items are missing or damaged, please contact your sales representative.
  • Page 7: Node Device

    Light Up Screen Press power button once Light on Reset Accumulated After the screen lights up, press Accumulated People Value and hold on the power button for 2s counting value reset Reset to Factory Press and hold on the reset Display reset frames Default button for 10s...
  • Page 8: Operation Guide

    4. Operation Guide 4.1 NFC Configuration VS360 can be and configured via NFC. Please refer to the following configuration steps. 1. Press power button for 5 seconds to power on both devices. 2. Download and install the Milesight ToolBox App from Google Play or Apple App Store.
  • Page 9: Lorawan ® Settings

    2) If the smartphone fails to read/write configurations via NFC, detach the phone from the device and try again. 3) Only the master device supports NFC and all configurations; the node device can adjust current emission intensity through its back panel to reduce power consumption . 4.2 LoRaWAN Settings ®...
  • Page 10 Network Session Nwkskey for ABP mode, the default is 5572404C696E6B4C6F52613230313823. Application Appskey for ABP mode, the default is Session Key 5572404C696E6B4C6F52613230313823. Device Address DevAddr for ABP mode, the default is the 5th to 12th digits of the SN. Select Standard-Channel mode or Single-Channel mode. When Single-Channel mode is enabled, only one channel can be selected to send uplinks.
  • Page 11: General Settings

    1) Please contact sales personnel for device EUI list if there are many units. 2) Please contact sales personnel if you need random App keys before purchase. 3) Select OTAA mode if you are using Milesight IoT cloud to manage devices. 4.3 General Settings...
  • Page 12: Advanced Settings

    Value Note: the device will reset automatically when accumulate counting values reaches 65535 even this option is disabled. The time to reset accumulated in/out counting values. Reset Time Note: The cumulative value will be reported once before reset. Disable or enable data storage locally. Data Storage Disable or enable data retransmission.
  • Page 13: Data Storage

    4.4.2 Data Storage VS360 supports the storage of 1000 data records locally and exports data via ToolBox App. The device will record the data according to the reporting interval even if it is disconnected from the network. Note that VS360 only stores periodic counting data.
  • Page 14: Data Retransmission

    5. Click Data Cleaning to clear all stored data inside the device if necessary. 4.4.3 Data Retransmission VS360 supports data retransmission to ensure the network server can receive all data even if the network is down for some time. There are two ways to retrieve the lost data: Network server sends downlink commands to enquire the historical data for a specified ...
  • Page 15: Milesight D2D Settings

    Milesight D2D protocol is developed by Milesight and is used for connection among Milesight devices without a gateway. When the Milesight D2D setting is enabled, VS360 can work as a Milesight D2D controller to send control commands to trigger Milesight D2D agent devices.
  • Page 16 Define a unique D2D key which is the same as the setting in D2D agent D2D Key devices. Default value: 5572404C696E6B4C6F52613230313823 When VS360 detects one or more of the below status, it will send the control command to the corresponding Milesight D2D agent devices: Someone entered ...
  • Page 17: Maintenance

    4.5 Maintenance 4.5.1 Backup VS360 supports backup templates for quick and easy device configurations in bulk. The backup feature is only for devices with the same model and LoRaWAN ® frequency band. 1. Go to Template page on the App and save the current settings as a template. The saved templates are also editable.
  • Page 18: Reset To Factory Default

    4.5.3 Reset to Factory Default VS360 supports two methods to reset the device, which are as follows: Via Hardware: Press and hold on the master device’s reset button for 10s . Via ToolBox App: Go to Device > Maintenance to tap Restore Factory Settings, then attach the...
  • Page 19: Installation Instruction

    5. Installation Instruction 5.1 Installation Node Device Determine the node device’s installation location first. Then choose one of ways to fix:  Fixed by 3M Tape Paste 3M tape to the back of device, tear the other side and attach it to the wall or other surfaces.
  • Page 20: Master Device

     Fixed by Mounting Kits 1. Take off the back cover of the device, and drill 2 holes in the wall according to the mounting holes on the cover. 2. Fix the wall plugs into the wall, then fix the back cover to wall plugs with screws. 3.
  • Page 21: Uninstallation

    1 Byte 1 Byte N Bytes 1 Byte 1 Byte M Bytes 1 Byte For decoder examples please find the files on https://github.com/Milesight-IoT/SensorDecoders. 6.1 Basic Information VS360 sensor reports basic information whenever it joins the network. Channel Type Byte Description...
  • Page 22: Sensor Data

    0b (Power On) Device is on 01(Protocol Version) 01=>V1 16 (Device SN) 16 digits 09 (Hardware Version) 01 40 => V1.4 0a (Firmware Version) 01 14 => V1.14 0f (Device Type) 00: Class A Example: ff0bff ff0101 ff166824e30817560003 ff090100 ff0a0101 ff0f00 Channel Type Value...
  • Page 23: Downlink Commands

    3. Abnormal Alarm: report when device is obstructed by an obstacle. 03f4 00 01 Channel Type Value 00 = Counting anomaly. 01= Alarm 6.3 Downlink Commands VS360 supports downlink commands to configure the device. The application port is 85 by default. Channel Item Type Byte Description Reboot...
  • Page 24 Byte 1: 00  Reporting Interval Byte 2-3: interval time, unit: min  Reset Accumulated 01: enable, 00: disable Value Accumulated 01: clear accumulate In counter Counter Clearing 02: clear accumulate Out counter Byte 1: Reset date  00: Everyday; 01: Every Sunday; 02: Every Monday;...
  • Page 25 Byte 4-5: Max. value  Byte 6-9: 00000000  Milesight D2D 01: enable; 00: disable Feature Milesight D2D Key First 16 digits, last 16 digits are fixed as 0 Byte 1:  01-Someone Entered 02-Someone Left 03-People Counting Threshold Triggered Byte 2: 01-enable, 00-disable ...
  • Page 26 Type Value 01=>Every Sunday ed (Reset Accumulated Reset hour: 0c => 12 Counter Time) Reset minute: 14=> 20 4. Set Milesight D2D Key as 5572404C696E6B4C0000000000000000. ff35 5572404C696E6B4C Channel Type Value 35 (Set D2D Key) 5572404C696E6B4C 5. Set Milesight D2D settings.
  • Page 27: Historical Data Enquiry

    6.4 Historical Data Enquiry VS360 supports sending downlink commands to enquire historical data for a specified time point or time range. Before that, ensure that the device time is correct and the data storage feature was enabled to store the data.
  • Page 28 1. Enquire historical data between 2023/8/28 13:30:00 to 2023/8/28 13:40:00. fd6cd830ec643033ec64 Channel Type Value Start time: d830ec64=> 64ec30d8 = 6c (Enquire data in time 1693200600s = 2023/8/28 13:30:00 range) End time: 3033ec64 => 64cc3330 = 1693201200s = 2023/8/28 13:40:00 Reply: fc6c00 Channel Type...