Page 1
Ultra ToF People Counter VS135-L08EU User Guide...
Page 2
Safety Precautions Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at the ToF sensor too close and directly.
Page 3
Revision History Date Doc Version Description Feb. 23, 2024 V 1.0 Initial version...
intelligent detection. Support video validation function to help customers verify statistical accuracy. High compatibility of data transmission(HTTP/MQTT). Support local data storage and data retransmission to collect data securely. Quick and easy management with Milesight DeviceHub. ...
Press and hold the power Turn On/Off: Blue light blinks for 3 seconds. Turn On/Off button for more than 3 Wi-Fi On: Blue light on. Wi-Fi seconds. Wi-Fi Off: Green light on. Press and hold the reset Reset to Green light blinks until the reset process is button for more than 10 Factory Default completed.
4. Access the Sensor VS135 provides user-friendly web GUI for configuration access via Wi-Fi. Users need to customize the password when using the device for the first time. The default settings are as below: Wi-Fi SSID: People Counter_xxxxxx (can be found on the device label) Wi-Fi IP: 192.168.1.1 Here are the wireless method way of accessing the web GUI: Step 1: Enable the Wireless Network Connection on your computer, search...
5. Operation Guide 5.1 Dashboard After logging on to the device web GUI successfully, user is allowed to view live video as following.
Page 10
Parameters Description Hide Capacity: Hide the total count data capacity; Staff Excluded: Exclude staff data from statistical data; Children Excluded: Exclude children data from statistical data. Reset Count Clear all accumulated entrance and exit people counting values. Click to output a 5s high level signal from alarm out interface. Digital Output Alarm Output: dry contact, output=two contacts closure Click to edit the preview layout.
detection regions as needed. 5.2 Rule Basic Counting Settings Users can draw detection lines to record the people count values which indicate the number of people enter or exit. Step 1: Click Draw Detection Lines. Step 2: Left-click to start drawing and drag the mouse to draw a line, left-click again to continue drawing a different direction edge, and right-click the mouse to complete the drawing.
Page 12
Note: The arrow direction of the detection line depends on your drawing direction. If users need to flip the line, select the line which need to be flipped and click Flip Arrow Direction. And users can click Flip All to flip all detection lines. Ensure that the detected target can pass through the detection line completely.
Page 13
Parameters Description Set the device installation height. Click Detect to detect the current installation height automatically. Note: Installation Height 1) Ensure that there is no object directly below the device avoiding interfering the height detection. 2) The automatic detection of the installation height is not supported...
Page 14
with dark floor/carpet (black, grey, etc.) Max. Target Set the maximum target height, then the device will ignore the objects Height higher than this setting value. Set the minimum target height, then the device will ignore the object Min. Target Height shorter than this setting value.
Step 3: The configuration is displayed in the list after the configuration is complete. You can redraw the areas by clicking the redraw button in the list. Click the edit button to modify the advanced settings of the areas or click delete button to delete the areas separately.
Page 16
VS135-L08EU supports Wi-Fi for web access and cellular for data transmission. WLAN Description .Parameters Enable or disable Wi-Fi feature. If disabled, users can use button to Enable WLAN enable it. The unique name for this device Wi-Fi access point, defined as Wi-Fi SSID People Counter_xxxxxx (can be found on the device label).
Page 17
provided by local ISP. The max length is 31 characters. Enter the username for cellular dial-up connection provided Username by local ISP. The max length is 31 characters. Enter the password for cellular dial-up connection provided Password by local ISP. The max length is 31 characters. PIN Code Enter a 4-8 characters PIN code to unlock the SIM.
network. Show the current PLMNID, including MCC, MNC, LAC, and PLMN ID Cell ID. Show the location code of the SIM card. Note: It will display "-" when the SIM card is not inserted or not recognized. Show the Cell ID of the SIM card location. Cell ID Note: It will display "-"...
Page 19
Parameters Description Recipient Name Customize the recipient name. Protocol HTTP(s) or MQTT is optional. Status Show connection status from device to HTTP server or MQTT broker. HTTP(s) Connection Test Click Test to send test message to URL to check connectivity. The device will post the people counting data in json format to this URL.
Page 20
It must be unique when all clients are connected to the same server, and it is the key to handle messages at QoS 1 and 2. Username The username used for connecting to the MQTT broker. Password The password used for connecting to the MQTT broker. Topic Topic name used for publishing.
Page 21
Parameters Description Status Show connection status between device and MQTT broker. Host MQTT address to receive data. Port MQTT port to receive data. Client ID is the unique identity of the client to the server. Topic It must be unique when all clients are connected to the same server, and it is the key to handle messages at QoS 1 and 2.
5.4 Report VS135 supports to generate visual line chart or bar chart to display the people traffic and supports to export the report. Before using this feature, ensure that the device time is correct on System page. Parameters Description Select the event which you want to query the report. Line crossing Event counting, region people counting, dwell time detection and heat map are optional.
Download the graph screenshot. 5.5 Validation Video validation function can assist users in verifying the accuracy of people counting by setting up a video task of recording. Note: Only one video task can be performed at a time, please delete the previous task before ...
Task can manually click "Stop Recording" to end the recording, or it will automatically stop when the recording time reaches 60 minutes. Configure the start time and duration of the recording. The duration can be set from 1 to 240 minutes. Clicking "Cancel Task"...
5.6.2 User Parameters Description You can change the login password of this device.
Page 26
Click to set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly. Click to add a viewer, who will only have access to the "Dashboard" and "Report"...
Setting Time Set the device time manually. 5.6.4 Remote Management Users can connect the device to the Milesight DeviceHub management platform on this page so DeviceHub as to manage the device centrally and remotely. For more details, please refer to...
Adjust the ToF frequency modulation mode to avoid the interference of Frequency surrounding IR devices. When using Multi-Device Stitching, please avoid using the same mode with other node devices. Adjustment Note: If there is only one option, please contact Milesight IoT support:...
Adjust the ToF light mode as Always On or Auto. When using Auto mode, the Lighting device will turn off the ToF light when radar detects no person for some times to save the power. Mode Enable to automatic compensation of person height values when the device is...
The maximum installation height is 3.5 m and the minimum installation height is h +d+Δd. For example, when the maximum pedestrian height is 1.8 m, then the minimum installation height is 1.8+0.5+0.035=2.335 m. The maximum installation height is 6.5 m and the minimum installation height is h +d+Δd.
7.82 × 5.71 3.91 × 2.85 8.05 × 5.87 4.14 × 3.02 High Ceiling Mount: Installation Height (m) Monitored Area (m) Detection Area(m) 4.04 x 2.90 2.08 x 1.49 4.27 x 3.07 2.31 x 1.66 4.50 x 3.23 2.54 x 1.82 4.73 x 3.40 2.77 x 1.99 4.97 x 3.56...
reflections that allow sunlight to shine on the ToF Sensor should be avoided. When the carpet/floor is black, ensure there is no obstacle within a 60cm hemisphere range in the direction of the device. Otherwise, the device imaging may appear abnormally red. 6.4 Installation Ceiling Mount Installation condition: ceiling thickness >...
Page 33
Note: Remove the rubber sleeve if waterproof is not required for easy installation. Use round wires. Ensure the rubber sleeve and the bottom cover are tightly connected without a gap if waterproof is required; if necessary, wrap the waterproof tapes around the wires to avoid any gap.
Page 34
Step 4: Remove the cover on the device, and then connect all required wires and pass them through the inside of pole. Step 5: Fix the pole to bracket base with screws and nuts. Ceiling Mount Lintel Mount Installation Note: Ensure that the ToF sensor is facing down and the tilt angle from the ground is no greater ...
with a distance of at least 40cm. When you install devices on the top of swinging doors, it is suggested to keep the door normally open. If the door must be normally closed, please install the device on the other side of the door to keep away from the door’s movement.