WINIX ZERO-N (AZNU230-HWE) - Air Purifier Manual

Also See for ZERO-N:

Advertisement

WINIX ZERO-N (AZNU230-HWE) - Air Purifier Manual

  • Please read and follow all safety rules and instructions in this manual before operating.
  • Please keep it in a safe place for future use.

This product is suitable for 220 - 240V, 50/60Hz only.

3-STAGE AIR PURIFICATION

3-STAGE AIR PURIFICATION

PACKAGE CONTENTS

PACKAGE CONTENTS

CONTROLS

CONTROLS

  1. Fan Speed Indicator
    Indicates the current fan speed.
  2. Change Filter Indicator
    LED light indicates when it is time to change the filter.
  3. Reset Button
    After replacing a filter, press the RESET button for at least 5 seconds.
  4. Air Quality Indicator
    Color-coded LED indicates one of three levels of air quality.
  5. Power Button
    Turns the unit on or off.
  6. Fan Speed Button (UP/DOWN)
    Enables Manual operation of the unit. Press to cycle through and set the desired fan speed (Low, Medium, High).
  7. Light Sensor
    Detects the amount of ambient light within the environment, to adjust the brightness of the LED indicators.

WHERE TO USE

Allow 30 - 45 cm. of space between TVs, radios, and other electronic products electromagnetic interference from certain electronics may cause product malfunction.

Place indoors away from direct sun light direct exposure may cause product malfunction or failure.

Only place on hard, flat surfaces flimsy or slanted surfaces may result in abnormal noise and vibrations.

WHERE TO USE


Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.

warning Do not use around mist or fumes from industrial oil or around large quantities of metallic dust.

warning Do not install in any sort of motor or transport vehicle (trucks, boats, ships, etc).

warning Do not place near any flammable materials (aerosols, fuel, gases etc).

warning Do not place below any electrical outlet.

warning Do not place around heating elements.

warning Do not place in an area with excessive amounts of noxious gases.

warning Do not have unit facing into wind or draft.

warning Do not place in excessively humid areas where unit may become wet.

This unit is not intended to be used to preserve documents or in art conservation.

INSTALLING FILTERS

This product comes with all required filters. The protective plastic wrap must be removed from the filter before use.

Operating the unit without removing the plastic wrap may result in product failure.

Unplug and make sure the unit is turned off before installing filter.

  1. Remove the front panel by pressing down on both edges of the front and gently pulling it toward the front.
  2. Press on the Pre-filter tabs near the top of the filter, release and remove.
  3. Remove the carbon filter from the filter case.
  4. Remove filters from protective plastic wrap.
    • Operating the unit without removing filters from plastic wrap may cause abnormal noise, deformation, or fire as a result of overheating.
  5. After removing the packing vinyl of the filter, insert the carbon filter into the filter case.
  6. Pull out the True HEPA filter.
  7. Remove the filter case, then remove the True HEPA filter.
  8. True HEPA filter Filter case in order, pushing it in close to the back of the product.
  9. After inserting both ends of the fabric pre filter, press both sides of the top to close it.
  10. Remove the fabric pre filter that is fastened to the front panel.
    • The fabric pre filter is secured by the 12 hooks on the back of the front panel.

When to service and replace filter

Filter Indicator Light When to service When to replace
  1. Fabric filter
none Clean once every 14 days Permanent
  1. Carbon filter
none Can NOT be WASHED Replace every 3 months
  1. True HEPA filter
Lasts up to 6~12 months

Intervals between filter replacement may vary depending on environment.

For optimal use, Fabric filter can be cleaned once every 14 days which can extend the life of other filters.

To purchase replacement Winix filters

contact your local dealer

Filter R:
Carbon filter and True HEPA filter

SAFETY AND CAUTIONS

Before operating this equipment, carefully read and follow these safety cautions

Ensure filters are inserted before running unit
running unit without filters can shorten the units life and cause electric shock or injury.

Be sure foreign objects are NOT inserted into the vents on the unit
objects can include pins, rods, and coins.

Do not touch any part of the interior of the unit with wet hands
the high voltage may cause electric shock.

Ensure unit intake and outlet vents do not become blocked
blockage may lead to increased internal temperatures causing product failure and deformation.

Do not use the unit as a step stool or place heavy objects on it
personal injury may occur or product failure and deformation.


Follow these instructions to reduce the risk of serious injury or death and to reduce risk of damaging the unit.

warning Do not pull on the power cord when unplugging the unit

warning If the unit becomes submerged in water, unplug it and contact customer service

warning Do not plug additional appliances into the same outlet or power supply

warning Unplug unit when not in operation for extended periods of time

warning Do not allow foreign objects such as pins, rods and coins to be inserted into the vents on the unit.

warning Do not tie or knot power cord when unit is in operation

warning Do not unplug or move the unit while in operation

warning Do not touch the plug with wet hands

warning Cord can become damaged by forcefully bending, pulling, twisting, bundling, pinching or placing heavy objects on it

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

This appliance is not intended for use by a person (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

INITIAL OPERATION

  1. Insert the power cord into an electrical outlet.
  2. Press the 'Power' button.
    NOTE
    • During the first 30 seconds of power up, the Air Quality Indicator will cycle through Blue, Amber and Red colors. The Particle Sensors take approximately 30 seconds to gauge the air quality in the environment, after which normal operation will begin.
  3. By default, when the unit first powers on, the mode will be set to Auto enabled.
    • When in Auto mode, the fan speed will be automatically adjusted according to the environments air quality.
NOTE
  • In Auto mode, as the indoor air quality improves, the fan speed will automatically be reduced to Low.
  • When the unit is running, you may hear a chirping or buzzing sound.

AUTO & SLEEP

Auto Mode

Enables auto operation based on the unit's air quality Particle Sensor.

  1. Press the Fan speed (UP/DOWN) button to select Auto mode.
    • The LED 'Auto' light will indicate when Auto mode is activated, and operation will begin.
NOTE
  • When in Auto mode the fan speed is automatically adjusted according to the indoor air quality. As the indoor air quality improves, the fan speed will automatically be reduced. If the indoor air quality decreases, the fan speed will automatically increase.

Sleep Mode

  1. Press the Fan speed (UP/DOWN) button to select Sleep mode.
    • The LED 'Sleep' light will indicate when Sleep mode is activated, and operation will begin.
NOTE
  • When Sleep mode is selected, the fan speed is automatically set to Low. The fan speed can be manually changed by pressing the Fan Speed button, changing the unit into manual mode.
  • When Sleep Mode is activated, the Air Quality Indicator LED light is disabled.

MANUAL & AIR QUALITY INDICATOR

Manual Mode (setting fan speed)

Users can optative to manually set the fan speed to Low, Medium, High.

  1. Press the Fan Speed button to set the desired fan speed.
NOTE
  • When Manual Mode is selected, Auto Mode is automatically disabled.

Air Quality Indicator

When on, the LED light will indicate the current indoor air quality according to three levels: BLUE (good), AMBER (fair), RED (poor).

NOTE
  • Air quality level is displayed on the indicator, based on the Particle Sensors. Depending on the immediate environment, the indicator may change frequently in color or stay the same for lengthy periods of time.

FILTER CARE

About The Filters

When the Check Filter indicator LED is on, it is time to replace the True HEPA filter.

Filter Indicator Light When to service When to replace
  1. Fabric filter
none Clean once every 14 days Permanent
  1. Carbon filter
none Can NOT be WASHED Replace every 3 months
  1. True HEPA filter
Lasts up to 6~12 months

Intervals between filter replacement may vary depending on environment.

For optimal use, Fabric filter can be cleaned once every 14 days which can extend the life of other filters.

To purchase replacement Winix filters

contact your local dealer

Filter R:
Carbon filter and True HEPA filter

Carbon filter and True HEPA filter

NOTE
  • The lifetime of a Filter is depending on the level of pollutants in the air. The more dust present in the environment, the more dust accumulates in the filters, shortening the life.
  • If the filters are heavily soiled or have a bad odour, or if the fan strength is significantly weakened, replace filters even if the Change Filter indicator has not yet turned on.

Resetting The Unit

  1. After replacing the filters, turn the power back on and then use a thin object, such as a paper clip, to press the RESET switch for 5 seconds.

Cleaning the Fabric Pre-filter

Intervals between filter cleaning may vary depending on the air quality.

  1. Use a vacuum cleaner or soft brush to clean the Fabric filter. If it is excessively soiled, rinse in room temperature water.
    • Do not use detergent or soap.
    • Allow the filter to dry for 24 hours or more before using

If the Fabric Pre-filter becomes damaged or in any way needs replacement: Please contact your local dealer

warning NOTICE
  • Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.
  • The Fabric Pre-filter is reusable after cleaning, ensuring it is completely dry.
  • Do not use hot water over 40oC or volatile fluids such as paint thinner.
  • After washing the filter, allow it to dry completely in a well ventilated area. Otherwise, it may develop a bad odour.

PARTICLE SENSOR CARE

Particle Sensors Care

For optimal performance of the Particle Sensor, which detects airborne dust and ultrafine particles, clean it every two months. Clean it more frequently when the unit is running in a place with high dust levels.

  1. Open the Particle Sensor cover.
  2. Use a damp cotton swab to wipe the lens and intake area of the Particle Sensor.
    • To clean the sensor area, use only water. Do not use volatile substances such as alcohol or acetone
  3. Wipe away any remaining moisture with a dry cotton swab.
  4. Close the Particle Sensor cover.
    • The Particle Sensors cover may be cleaned using a vacuum cleaner

CLEANING CARE

Cleaning the Exterior & Interior

  1. Wipe with a soft damp cloth using room temperature water. Afterwards, wipe it down with a clean dry cloth.
    • To keep unit in peak condition, clean every 1-2 months.
  2. Open the front panel and clean the interior with a vacuum cleaner.
    • For optimal performance, clean every 1-2 months.
warning NOTICE
  • When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled down.
  • Never disassemble, repair, or modify this unit yourself.
  • Do not use flammable sprays or liquid detergents.
  • Do not allow children to clean or maintain the unit.
  • Before cleaning or maintaining, ensure unit is unplugged.

FREQUENTLY ASKED QUESTIONS

Problem Check / Actions to take
It does not turn on at all.
  • Is the plug securely attached to the outlet?
    • Make sure the outlet has power going to it, and ensure the plug is secured.
  • Is there a power outage?
    • Check to see if other lights and electrical equipment are working and try again.
It doesn't work in Auto Mode.
  • Has Auto Mode been selected?
    • Press the Mode button until Auto Mode is selected.
  • Is the sensor blocked or clogged?
    • Wipe Odour Sensor with wet cloth, then dry.
It vibrates and makes a lot of noise.
  • Is it running on a slanted or uneven surface?
    • Move the unit to a hard, flat, even area of the floor.
The power plug and outlet feel hot.
  • Is the plug securely plugged in?
    • Make sure the plug is properly plugged into the outlet.
There is a strange smell.
  • Is it being used in a place with a lot of smoke, dust, or odours?
    • Clean the air intakes on either side and clean the Fabric filter.
    • Clean or change the filter.
The fan strength is weak. The unit is not purifying the air.
  • Is the Check Filter indicator light on?
    • Change the filters as required.
The display panel is dim.
  • Is the Light Sensor blocked by debris?
    • When Auto Mode is on, Sleep Mode is automatically activated when the Light Sensor detects that the room is dark.

UNIT SPECIFICATIONS

Model Name ZERO-N (AZNU230-HWE)
Power Voltage AC 220 - 240 V, 50 / 60 Hz
Power Rate 30 W
Max Room Capacity 45 m2
Dimensions 350 mm(W) x 207 mm(D) x 470 mm(H)
Weight 6.2 kg
Replacement Filter Filter R / item: 1712-0088-00

The exterior, design and product specifications may be changed without prior notice to improve product performance.

Contact your local dealer for product related inquiries and customer service

WWW.WINIX.COM/EU

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download WINIX ZERO-N (AZNU230-HWE) - Air Purifier Manual

Advertisement

Need Assistance?

Do you have a question about the ZERO-N that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents