REPAIR INSTRUCTIONS
6. Replacing ELECTROVALVE 37
To prevent damage to the electrovalve during service activity, please observe below precautions during disassembly
& reassembly.
Tools required: Torque wrench (set to 6 kgf)
CAUTION #1: The torque wrench engagement is allowed ONLY at the yellow box locations in below picture.
Contact area for torque
wrench to screw/unscrew
the electrovalve.
CAUTION #2: Ensure torque wrench jaw does not contact the solenoid body.
Maintain gap between
the torque wrench and
the solenoid body
Torque wrench
Electro-valve
solenoid body