Troubleshooting - Crown GC-12 Installation & Operation Manual

Gas fired steam jacketed tilting kettle
Hide thumbs Also See for GC-12:
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, GAS FIRED TILTING KETTLE, MODEL GC-12

9.0 TROUBLESHOOTING

Unit does not come on:
1.
Power switch and/or thermostat is "OFF".
2.
Unit is not plugged in.
3.
Main power supply is off.
4.
Tilt micro switch out of alignment or faulty.
Unit is on electrically but does not heat:
1.
Gas supply to the unit is "OFF".
2.
The manual shut-off valve is "OFF".
3.
The thermostat is not turned "ON."
4.
The kettle is not in the upright position.
5.
The electronic ignition is not functioning.
6.
Pressure switch is not functioning.
7.
Low water in kettle jacket.
8.
Thermostat is not functioning.
Unit is slow to preheat and slow to recover:
1.
Wrong size orifices.
2.
Wrong gas supply.
3.
Incorrect pressure at supply.
4.
Loss of vacuum.
NOTICE: Contact the factory, the factory representative or local service company
to perform maintenance and repairs.
PART NO. 10105R6
17
2013-07-11