Troubleshooting - Crown GLT-80 Installation & Operation Manual

Gas fired steam tilting
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Loose, broken or grounded wiring may cause many of the symptoms listed.
Unit will not come on
Unit will turn on electrically
but will not heat
Excessive flame rollout on
ignition, carboning
Unit slow to preheat and
slow to recover
Unit continuously locks out
20
PAGE
OF 32
Check all wiring and make sure it is intact.
PROBLEM
Main power switch is off.
Unit not plugged in.
Main power supply off.
Bad electronic module.
Bad low water control.
Bad spark igniter.
Bad intermittent pilot burner.
Fuse in unit blown.
Lockout has occurred.
Thermostat not on.
Gas control valve off.
Main gas supply off.
Low water.
Bad thermostat.
Bad pressure switch.
Bad gas control valve.
Bad spark igniter.
Bad igniter cable.
Bad intermittent pilot burner.
Faulty gas control.
Natural gas unit on propane.
Excessive gas pressure.
Incorrect orifice size.
Faulty regulator in gas control.
Propane gas on natural.
Low gas pressure.
Incorrect orifice sizes.
Loss of vacuum.
Faulty regulator in gas control.
Pilot gas adjusted too low.
Excessive draft condition.
Excessive steam around bottom of unit during operation of cleaning.
Faulty transformer.
Faulty electronic module.
Faulty ignitor cable.
Faulty spark igniter.
Faulty gas control.
INSTALLATION & OPERATION MANUAL 10325 REV 1 (11/21)
Gas Fired Steam Tilting Kettles
NOTICE
PROBABLE CAUSE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glt-100

Table of Contents