ABB L150 User Manual page 42

1/8 din level indicator, inform industrial enabled it
Hide thumbs Also See for L150:
Table of Contents

Advertisement

...SPECIFICATION
Analog Input
Input type
1 to 10 mA, 4 to 20 mA or customize via PC Configurator
Input sampling rate
250ms
Accuracy
Indicator
Output
Sensor power supply
24V, 30mA max. (powers one 2-wire transmitter)
± 3V, 15mA (power for P851/P861 sensors)*
*Option board
Outputs – Standard Build
Retransmission
Analog, configurable in the range 4 to 20mA
Max. load
Isolation
Logic output
18V DC at 20mA
Min. load
Isolation
Relay output
One relay as standard (SPDT) 5A at 115/230V AC, assignable to alarms
Option
One option board can be installed from:
Type 00
Type 01
Type 02
Type 03
Type 04
40
0.2% of reading
<0.2% of span
15V (750 at 20mA)
500V DC from sensor input (not isolated from logic output)
400
500V from sensor input (not isolated from retransmission output)
One relay + retransmission + logic output (Standard Build)
Two relays + retransmission + logic output
Three relays + retransmission + logic output + digital input
Two relays + retransmission + logic output + digital input +
RS485/Modbus
Two relays + retransmission + logic output +
P851/P861 power supply

Advertisement