ABB L150 User Manual page 23

1/8 din level indicator, inform industrial enabled it
Hide thumbs Also See for L150:
Table of Contents

Advertisement

...4.3.2 Alarms – Figs. 4.3, 4.4, 4.5 and 4.6
E
0000
Display
None
0
High Process
1
Low Process
2
High Latch
3
Low Latch
4
Fast Rate
5
Slow Rate
6
F
0000
Display
None
0
High Process
1
Low Process
2
High Latch
3
Low Latch
4
Fast Rate
5
Slow Rate
6
h 0000
Display
None
0
0.1%
1
0.2%
2
0.5%
3
1.0%
4
2.0%
5
5.0%
6
Custom
U
E – Alarm 1 Type
F – Alarm 2 Type
H – Alarm Hysteresis
Value in % of
engineering range
See Note
Fig. 4.3 Alarm Types
4 CONFIGURATION MODE...
G
0000
Display
None
0
High Process
1
Low Process
2
High Latch
3
Low Latch
4
Fast Rate
5
Slow Rate
6
Note. When custom alarm
hysteresis is selected, the
alarm hysteresis values must
first be set individually in the
Set Up Level
G – Alarm 3 Type
– see Section 3.2
21