Confi Guration Of The System And Confi Guration Of The Inputs; And Outputs - Daikin HUBBARD HCU2040PXB1 Installation, Commissioning And Maintenance Manual

Hermetic r744 condensing units
Table of Contents

Advertisement

ENG
Accessories:
Code
Description
PGDERK1FX0
pGD evolution user terminal for pRack pR300T
Module to convert a 0...10V analog output to an SPDT
CONVONOFF0
digital output
CVSTDUTLF0
USB/RS485 serial convertor with telephone connector
CVSTDUMOR0 USB/RS485 serial converter with 3-way terminal
PCOSO0AKY0
Smart Key programming key
S90CONN002
Connection cable for terminal 1=0.8m
S90CONN000
Connection cable for terminal 1=1.5m
S90CONN001
Connection cable for terminal 1=3 m
SPKT*R* and
Ratiometric pressure probes 0...5 Vdc
SPKC00*
SPK*C*, SPK1*,
Active pressure probes 4...20 mA
SPK2*, SPK3*
NTC*
Pressure probe NTC -50T90°C
NTC*HT*
Pressure probe NTC -0T150°C
EVD0000E50
EVD EVO universal driver for Carel valves, RS485/Modbus
EVDIS00D*0
Display for EVD EVO
E2VCABS*00
EVD-valve connection cable
1.3 Confi guration of the system and
confi guration of the inputs and outputs
pRack pR300T has the same system confi guration management and
input and output confi guration management as the standard pRack.
Note: each input/output is completely confi gurable with the only
requirements being those set by the system confi guration. For
example, the suction pressure probe on line 1 can be arbitrarily confi gured
to any one of the analog inputs in the pLAN control board with address 1
compatible with the type of probe.
1.3.1
System confi gurations available
pRack pR300T can manage system confi gurations with up to 2 suction
lines (maximum 12 scroll or piston compressors for lines 1 and 2) and up
to 1 high pressure line (maximum 16 fans per line). When there are two
suction lines, the lines can be managed by the same pRack board or by
separate boards. The condenser line can be managed by the board that
manages the suction line, or by a separate board, in accordance with the
number of inputs/outputs available.
For each line, both suction and condensing, pRack pR300T can manage
a modulating device (inverter, Digital Scroll® compressor or compressor
with continuous control).
Example 1: 1 suction line with scroll or piston compressors, 1 high pressure
line:
I/O
J11 pLAN
J10
pR300T
FieldBus card
J1
J24
J2
I/O
Copyright HPL March 2021
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
J1 5
J1 2
J1 3
J1 4
4
3
2
1
J2 5 BMS2
J2 6 FBus2
B M S card
J3
J4
J5
Fig. 1.a
Example 2: 2 suction lines on the same board with scroll or piston
compressors, 1 high pressure line:
TM
Tab. 1.d
Example 3: 2 suction lines on separate boards (scroll or piston
compressors), 1 high pressure line (on the fi rst suction line board):
J10
J1
Example 4: 2 suction lines on separate boards with scroll or piston
compressors, 1 high pressure line on separate board:
J10
pLAN
J1
J10
J1
Note: if connecting more than one pRack pR300 board in a pLAN,
mixed networks cannot be created combining Compact boards and S, M,
L boards, while mixed networks are possible using combinations of the
latter models only.
Important: all the boards connected to the pLAN must have the
same software revision.
6
Page 55 of 169
I/O
pR300
pR300T
I/O
I/O
Fig. 1.b
I/O
pLAN
J1 5
J1 2
J1 3
J1 4
J11 pLAN
J11 pLAN
J10
4
3
2
1
J2 5 BMS2
J2 6 FBus2
pR300
pR300T
pR300
pR300T
FieldBus card
B M S card
J24
J2
J3
J4
J5
J1
J24
I/O
I/O
Fig. 1.c
I/O
J1 5
J1 2
J1 3
J1 4
J11 pLAN
4
3
2
1
J2 5 BMS2
J2 6 FBus2
pR300
pR300T
FieldBus card
B M S card
J24
J2
J3
J4
J5
pLAN
J1 5
J1 2
J1 3
J1 4
J11 pLAN
J11 pLAN
J10
4
3
2
1
J2 5 BMS2
J2 6 FBus2
pR300T
pR300
pR300T
pR300
FieldBus card
B M S card
J4
J5
J24
J2
J3
J1
J24
I/O
I/O
Fig. 1.d
P4367 Rev 01
J1 5
J1 2
J1 3
J1 4
4
3
2
1
J2 5 BMS2
J2 6 FBus2
FieldBus card
B M S card
J2
J3
J4
J5
J1 5
J1 2
J1 3
J1 4
4
3
2
1
J2 5 BMS2
J2 6 FBus2
FieldBus card
B M S card
J4
J5
J2
J3