Daikin HUBBARD HCU2040PXB1 Installation, Commissioning And Maintenance Manual page 113

Hermetic r744 condensing units
Table of Contents

Advertisement

ENG
Mask index
Display description
Daf04
Refrigerant type
Daf05
Device rotation type
Daf07, Daf08
Custom rotation
on order
Daf09, Daf10
Custom rotation
off
Dag01
Speed modul. device
Dag02
Standby zone reg.
Min out value
Max out value
Min. power ref.
Max. power ref.
Dag03
Rising time
Falling time
Num. control. fans
Dag04
Split Condenser
Controlled by:
-Digital input
-External temp
-Scheduler
Dag05
Ext.Temp.Set.
Ext.Temp.Diff .
Dag06
Type
---
Dag09
Disable split condenser as
fi rst stage of HP pressure
switch
for
Dag10
Silencer
Max output
Controlled by:
-Digital input
-Scheduler
Dag12
-
TB1: --:-- -> --:--
...
TB4: --:-- -> --:--
Change
Copy to
Dag13
Speed Up
Speed up time
Ext.Temp.Mgmt
Ext.Temp.Set.
Diff . Ext.Temp.
Dag14
Enable gas cooler press.
backup probe
Dag15
Request in case of regulation
probe fault
The following parameters refer to line 2, for details, see the corresponding parameters for line 1 above
Dba01
DI
Status (display only)
Logic
Function (display only)
Dba39
---
---
--- (display only)
Max limit
Min limit
Calibrat.
...
...
Dbb01
Regulation
Regulation type
...
...
Copyright HPL March 2021
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
Description
Type of refrigerant (condensing line 1)
Type of rotation devices (condensing line 1)
On order for devices for custom rotation (condensing line 1)
Off order for devices for custom rotation (condensing line 1)
Modulating condenser device type (line 1)
Fan modulation even in dead zone (line 1)
Minimum voltage for compressor inverter (line 1)
Maximum voltage for compressor inverter (line 1)
Minimum capacity of fan modulating device (line 1)
Maximum capacity of fan modulating device (line 1)
Time to pass from minimum to maximum capacity for fan modulating device (line 1)
Time to pass from maximum to minimum capacity for fan modulating device (line 1)
Number of fans under inverter (only for alarm enabling)
Enable split condenser (line 1)
Split condenser controlled by digital input (line 1)
Split condenser controlled by external temperature (line 1)
Split condenser controlled by scheduler (line 1)
Split condenser setpoint by external temperature (line 1)
Split condenser diff erential by external temperature (line 1)
Fans enabled with split condenser (line 1)
Only when enabling is GREATER THAN or LESS THAN the number of fans to consider (line 1) 0
Disable split condenser when high condensing pressure prevent occurs (line 1)
Duration of split condenser deactivation for high pressure prevent (line 1)
Enable silencer (line 1)
Maximum possible request when silencer is active (line 1)
Silencer controlled by digital input (condensing line 1)
Silencer controlled by scheduler (condensing line 1)
Day of the week
Enabling and defi nition of time band 1: start hour and minute, end hour and minute
(condensing line 1)
...
Enabling and defi nition of time band 4: start hour and minute, end hour and minute
(condensing line 1)
Time band change action
Copy settings to other days
Enable speed up (condensing line 1)
Speed up time (condensing line 1)
Enable speed up management by external temperature (condensing line 1)
Speed up management by external temperature threshold (condensing line 1)
Speed up management by external temperature diff erential (condensing line 1)
Enable screens for the confi guration of the gas cooler pressure backup probe (condensing
line 1)
Value of fan forcing in case of gas cooler probe error (line 1)
Fan 1 overload DI position (line 2)
Fan 1 overload DI status (line 2)
Fan 1 overload DI logic (line 2)
Fan 1 overload function status (line 2)
Intercooler pressure probe position (downstream)
Intercooler pressure probe type (downstream)
Intercooler pressure value (downstream)
Maximum intercooler pressure value (downstream)
Minimum intercooler pressure value (downstream)
Intercooler pressure probe calibration (downstream)
...
Condenser regulation by temperature or pressure (line 2)
Condenser regulation Type (line 2)
...
64
Page 113 of 169
Def.
U. of M.
Values
R744
---
R22
| R134a
R404A | R407C
R410A | R507A
R290 | R600
R600a | R717
R744 | R728
R1270 | R417A
R422D | R413A
R422A | R423A
R407A | R427A
R245Fa | R407F | R32
FIFO
---
------
FIFO
LIFO
TEMPO
CUSTOM
1
---
1...16
1
---
1...16
None
---
None | Inverter
Phase cut-off control
NO
---
NO | YES
0.0
V
0.0...9,9
10.0
V
0.0...99,9
60
%
0...100
100
%
0...999
1200
s
0...32000
1200
s
0...32000
1
---
0...16
NO
---
NO | YES
---
---
NO | YES
---
---
NO | YES
---
---
NO | YES
10.0 °C
...
-99,9...99,9
2,5 °C
...
-99,9...99,9
custom
---
Custom
Odd
Even
Greater than
Less than
---
0...16
NO
---
NO | YES
0
h
0...24
Disabled
---
Disabled
Abled
75.0 %
%
0.0...100.0
NO
---
NO | YES
NO
---
NO | YES
---
---
LUN, ..., DOM
---
...
...
...
...
...
---
...
...
---
---
---
Save changes
Load previous
Clear all
0
---
MONDAY...SUNDAY;
MON-FRI;
MON-SAT;
SAT&SUN; ALL
YES
---
NO | YES
5
s
0...60
Disabled
---
Disabled | abled
25.0 °C
...
-99,9...99,9
2,5 °C
...
-99,9...99,9
NO
---
NO | YES
50.0
%
0.0...100.0
...
---
--- | 01...18 |
U1...U10 (****)
---
---
closed | open
NC
---
NC | NO
---
---
not active | active
---
---
U1...U10 (****)
4...20mA
---
---- | 0-1V | 0-10V
4...20mA | 0-5V
---
...
...(**)
44.8 barg
...
...(**)
0.0 barg
...
...(**)
0.0 barg
...
...(**)
...
...
...
pressure
---
pressure
temperature
Proportion.
---
proportional Band
band
dead zone
...
...
...
P4367 Rev 01