Daikin HUBBARD HCU2040PXB1 Installation, Commissioning And Maintenance Manual page 119

Hermetic r744 condensing units
Table of Contents

Advertisement

ENG
Mask index
Display description
Eib25
Threshold
Diff .
Delay
Reset
Swith-off comp.
Eib27
Enable parallel compressor:
Eib28
RPRV opening:
Delay:
Min g.c.temp.:
Eib31
Receiver pressure threshold
Time
Var. delta
Eib32
Max. HPV valve opening
percentage
Max. delta
Eib35
Min on time:
Min off time:
Min time to start same
compressor:
Eib40
RPRV off set with par. compr.
On:
Par. Comp. ON Rising time
RPRV:
Par. Comp. Off Falling time
RPRV:
Eic01
HPV Valve
RPPV Valve
EVD address
Valves routing
EVD Status
Eic02
HPV Valve type
RPRV Valve type
Eic03
Min. steps
(Valvola HPV)
Max. steps
closing steps
Nom. step rate
Move current
Holding current
Eic04
Duty Cycle
(Valvola HPV)
Opening sincre
Closing sincre
Em. closing speed
Eic05
Min. steps
(Valvola RPRV)
Max. steps
closing steps
Nom. step rate
Move current
Holding current
Eic06
Duty Cycle
(Valvola RPRV)
Opening sincre
Closing sincre
Em. closing speed
The following parameters refer to line 2, for details, see the corresponding parameters for line 1 above
Eaba04
---
---
--- (display only)
Max limit
Min limit
Calibration
...
...
Eabb04
Enable com.cool.
Number of oil pumps
Enable pump out.
...
...
Ebba01
DO
Status (display only)
Logic
Function (display only)
...
...
Ebbb01
Subcooling contr.
---
Threshold
Subcooling (display only)
Copyright HPL March 2021
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
Description
Receiver high pressure threshold alarm
Receiver high pressure diff erential alarm
Receiver high pressure alarm delay
Receiver high pressure alarm reset type
Enable compressor shutdown when high pressure receiver alarm occurs
Enable parallel compressor
RPRV opening to allow parallel compressor
Delay on parallel compressor activation
Minimum GC temperature to allow parallel compressor
Threshold pressure for the gas cooler when the Heat Reclaim is ON
Time during which this threshold remains active
Allowed variation
HPV valve maximum opening
HPV valve maximum variation per second
Parallel compressor by inverter, timings. Min on time
Parallel compressor by inverter, timings. Min off time
Parallel compressor by inverter, timings. Min time to start same compressor
Increment of RPRV setpoint during parallel compressor regulation
Rising time of RPRV setpoint
Falling time of RPRV setpoint
Enable EVS management of HPV valve
Enable EVS management of HPV valve RPRV
Driver address managed in FBUS from pRack
Valve type driver association
Driver connection to pRack status
HPV valve type
RPRV valve type
Minimum valve step number
Maximum valve step number
Valve closing steps
Valve nominal speed
Nominal current
Holding current
Valve duty cycle
Opening position synchronization
Closing position synchronization
Valve emergency closing speed
Minimum valve step number
Maximum valve step number
Valve closing steps
Valve nominal speed
Nominal current
Holding current
Valve duty cycle
Opening position synchronization
Closing position synchronization
Valve emergency closing speed
Oil temperature probe position (line 2)
Oil temperature probe type (line 2)
Oil temperature value (line 2)
Maximum oil temperature value (line 2)
Minimum oil temperature value (line 2)
Oil temperature probe calibration (line 2)
...
Enable common oil cooling (line 2)
Number of oil pumps for common oil cooler (line 2)
Enable AO of common oil cooler pump (line 2)
...
Subcooling DO valve position (line 2)
Subcooling DO valve status (line 2)
Subcooling DO valve logic (line 2)
Status of the subcooling valve function (line 2)
...
Enable subcooling function (line 2)
Subcooling control type (line 2)
Threshold for subcooling activation (line 2)
Subcooling value (line 2)
70
Page 119 of 169
Def.
U. of M.
Values
45.0 barg
...
... (**)
5.0 barg
...
... (**)
30
s
0...9999
manual
---
manual | auto
NO
---
NO | YES
NO
YES | NO
30
%
10
s
0...999
15
°C/°F
---
---
---
---
---
---
---
---
---
0
%
0.0...100.0
0
%
0.0...100.0
30
s
30
s
60
s
2
barg
0
s
20
s
enable
---
enable | disable
enable
---
enable | disable
198
---
0..207
---
---
Single A->HPV
Single A->RPRV
Twin A->RPRV
B->HPV
Twin A->HPV
B->RPRV
---
---
connected
not connected
CAREL EXV ---
CAREL EXV,
CUSTOM, Danfoss
CCMT, Danfoss
ICMTS (0-10V)
CAREL EXV ---
CAREL EXV, CUSTOM,
Danfoss ETS 400,
Danfoss ETS 250,
Danfoss ETS 100B,
Danfoss ETS 50B,
Danfoss ETS 12.5-25B,
Danfoss CCM 40
Danfoss CCM 10-20-30
Danfoss ICMTS
(0-10V)
50
step
0...9999
480
step
0...9999
500
step
0...9999
50
step/s
1...2000
450
mA
0...800
100
mA
0...250
30
%
0...100
YES
-----
YES | NO
YES
------
YES | NO
150
step/s
1...2000
50
step
0...9999
480
step
0...9999
500
step
0...9999
50
step/s
1...2000
450
mA
0...800
100
mA
0...250
30
%
0...100
YES
-----
YES | NO
YES
------
YES | NO
150
step/s
1...2000
B1
---
---, U1...U10 (****)
4...20 mA
---
--- | NTC | PT1000
| 0...1 V | 0...10 V |
4...20 mA | 0...5 V |
HTNTC
---
...
...(**)
30.0 barg
...
...(**)
0.0 barg
...
...(**)
0.0 barg
...
...(**)
...
...
...
YES
---
NO | YES
0
---
0...1 (analog. output)
0...2 (digital outputs)
YES
---
NO (digital outputs)
YES (analog. output)
...
...
...
...
---
---, 01...18 (****)
---
---
closed | open
NO
---
NC | NO
---
---
not active | active
...
...
...
NO
---
NO | YES
Temp.
---
Temp. Cond&Liquid
only Liquid Temp.
Cond&Liqu.
0.0 °C
...
-9999,9...9999,9
0.0 °C
...
-999,9...999,9
P4367 Rev 01