Power Speci Cations - ComfortStar CPA-09B Owner's Manual & Installation Manual

Middle static pressure duct type air conditioner, indoor/outdoor unit
Hide thumbs Also See for CPA-09B:
Table of Contents

Advertisement

(if supplied and packed with the
Magnetic ring
accessories)
1 2 3
Power Specifications (Not applicable for North America)
NOTE: Electric auxiliary heating type circuit breaker/fuse need to add more than 10 A.
MODEL(Btu/h)
POWER
CIRCUIT BREAKER/
FUSE(A)
MODEL(Btu/h)
POWER
CIRCUIT BREAKER/FUSE(A)
MODEL(Btu/h)
POWER
CIRCUIT BREAKER/
FUSE(A)
MODEL(Btu/h)
POWER
CIRCUIT BREAKER/FUSE(A)
Pass the belt through
the hole of the Magnetic
ring to fix it on the cable
Indoor Power Supply Specifications
≤18K
PHASE
1 Phase
208-240V 208-240V 208-240V 208-240V 208-240V
VOLT
25/20
≤36K
PHASE
3 Phase
380-420V
VOLT
25/20
Outdoor Power Supply Specifications
≤18K
PHASE
1 Phase
208-240V 208-240V 208-240V 208-240V 208-240V
VOLT
25/20
≤36K
PHASE
3 Phase
380-420V
VOLT
25/20
CAUTION
While connecting the wires, please strictly follow
the wiring diagram.
The refrigerant circuit can become very hot.
Keep the interconnection cable away from the
copper tube.
4. Clamp down the cable with the cable clamp.The
cable must not be loose or pull on the u-lugs.
5. Reattach the electric box cover.
19K~24K 25K~36K 37K~48K 49K~60K
1 Phase
1 Phase
32/25
50/40
37K~60K
3 Phase
3 Phase
380-420V
208-240V
32/25
32/25
19K~24K 25K~36K 37K~48K 49K~60K
1 Phase
1 Phase
32/25
50/40
37K~60K
3 Phase
3 Phase
380-420V
208-240V
32/25
32/25
1 Phase
1 Phase
70/55
70/60
≤36K
37K~60K
3 Phase
208-240V
45/35
1 Phase
1 Phase
70/55
70/60
≤36K
37K~60K
3 Phase
208-240V
45/35
Page 35