Parameter Descriptions; Group - Display And Diagnostic Parameters (Read Only) - Allen-Bradley 161S-AA04NPU User Manual

Table of Contents

Advertisement

Parameter Descriptions

D Group - Display and Diagnostic Parameters (Read Only)
This group of parameters consists of commonly viewed drive operation conditions such as output
frequency. All parameters in this group are Read Only.
Parameter
Parameter Name / Description
Number
Display and Diagnostic Functions
d01
[Output Frequency]
Displays the output frequency to the motor.
d02
[Output Current]
Displays the output current to the motor.
d03
[Direction]
Displays the present direction of rotation.
F=Forward
r=Reverse
o=Stop
d04
[PID Process Display]
Displays the scaled PID Process variable (feedback), this is
only available when the PID control is active. The scale factor
is set using parameter C15 - [Digital Input 5 Logic].
d05
[Digital Input Status]
Displays the status of the 5 digital inputs regardless of how
each input is programmed in parameter C11 - [Digital Input 1
Logic] through parameter C15 - [Digital Input 5 Logic].
5 4 3 2 1
d06
[Output Status]
Displays the status of the digital outputs and the fault
indication relays.
d07
[Process Display]
Displays parameter d01 - [Output Frequency ] scaled by the
variable set in parameter b86 - [Process Display Scale Factor].
Note: If there are more than 4 digits, the LSB will be dropped.
d08
[Last Fault]
Displays the last fault. The output frequency, motor current,
and DC-bus voltage at the time of the last fault can be viewed
by pressing the SELect key. If there has not been a fault or the
register has been cleared, then --- will be displayed.
d09
[Fault Register]
Displays the 2
this register, then --- will be displayed. To view the 3
press the SELect key.
d16
[Elapsed Run Time]
Displays the elapsed running time of the drive. The elapsed
running time is the displayed value x 10.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Active
Inactive
AL12 11
Active
Inactive
nd
rd
and 3
fault, if there are no faults stored in
Parameters & Programming
Min./Max
Range
0.0/360.0
0.00/
999.9
Alpha
Numeric
Value
0/100.0
N/A
N/A
0.00/9999
N/A
N/A
rd
fault,
0/9999
Units
0.1 Hz
0.01A
Alpha
Numeric
Value
0.01%
N/A
N/A
0.01
---
---
10
hours
21

Advertisement