Hoover HIFS954MCTT Instruction Manual page 15

Table of Contents

Advertisement

Available languages

Available languages

Power management Rule
s
If total power exceeds the limitation of 2.5kw, 3.0kw, 4.5kw, 6.5kw,7.4kw
(depending on which level you've set), you are not able to increase power stage
of any zone.
If you increase it, the cooktop will beep 3 times and indicator will show a flashing
'Pn'. Thus you need to decrease power stage of other zones before increasing the
power of objective zone.
Power Managemen
t
• Cooking zones are divided into two groups. Each group has a maximum
electricity loading of 3600 W.
• The limitation decreases the power to the other cooking zones in the same group.
• The heat setting display of the reduced zones changes between two levels
.
In Group a, both two zones can work at level 9 at the same time because they
are 3500 W in total.
In Group b if 3 zones are working, the max power level which each zone can
reach is 7. If you want one of the zone of Group b works at the highest power
level, only 2 zones can be turned on at most. The power level of first hob will
reduces automatically when reach power limitation.
EN-14