Advertisement

Quick Links

INSTRUCTION MANUAL
INJECTION UNIT
For LIGHTENING SURGE SIMULATOTR
LSS-6000 SERIES
MODEL: LSS-INJ6400SIG
NOISE LABORATORY CO., LTD.
2.01Edition
AEE00146-00E-1B

Advertisement

Table of Contents
loading

Summary of Contents for NoiseKen LSS-6000 Series

  • Page 1 INSTRUCTION MANUAL INJECTION UNIT For LIGHTENING SURGE SIMULATOTR LSS-6000 SERIES MODEL: LSS-INJ6400SIG NOISE LABORATORY CO., LTD. 2.01Edition AEE00146-00E-1B...
  • Page 2 NOTICE The contents of this booklet are subject to change without prior notice. No part of this booklet may be reproduced or transferred, in any form, for any purpose, without the permission of Noise Laboratory Co., Ltd. The contents of this booklet have been thoroughly checked. However, if a doubtful point, an error in writing or a missing is found, please contact us.
  • Page 4 (157A maximum) by surge from LSS-6000 series, carefully handle it. Mishandling or careless operation may result in a fatal wound. 2. Use of the unit and the lightning surge simulator (LSS-6000 series) unit in an explosive area such as "No fire" area etc. is prohibited. If used in such an area, it is liable to cause combustion or ignition due to discharge.
  • Page 5 Memorandum...
  • Page 6 2. APPLICATION FORM FOR INSTRUCTION MANUAL We place an order for an instruction manual. Model: LSS-INJ-6400SIG Serial No.: Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No. Cut off this page "APPLICATION FORM FOR INSTRUCTION MANUAL" from this volume and keep it for future use with care. When an INSTRUCTION MANUAL is required, fill in the above Application Form and mail or fax it to the following sales department of our company.
  • Page 7 Memorandum...
  • Page 8: Table Of Contents

    3. TABLE OF CONTENTS 1. IMPORTANT SAFETY PRECAUTIONS ..............1 2. APPLICATION FORM FOR INSTRUCTION MANUAL ....... 3 3. TABLE OF CONTENTS ..................... 5 4. PREFACE ..............................6 4-1 PREFACE ................................6 4-2 F ........................... 6 UNCTIONS AND CAPABILITIES 5. BASIC SAFETY PRECAUTIONS .................
  • Page 9: Preface

    The unit is just only for Lightening Surge Simulator (LSS-6000 Series). For details about how to use Lightening Surge Simulator (LSS-6000 Series), refer to the instruction manual of each model. 4-2 Functions and capabilities The unit is used for the surge immunity tests for interconnection lines described in IEC61000-4-5.
  • Page 10: Basic Safety Precautions

    DC line out connector, DC line in terminal in conducting tests because high voltage is generated. 2. Use of the unit and the lightning surge simulator (LSS-6000 series) unit in an explosive area such as "No fire" area etc is prohibited. If used in such an area, it is liable to cause combustion or ignition due to discharge.
  • Page 11 11. Connect the connection plug, the capacitor / arrestor unit, the arrestor unit, and the surge protection arrestor correctly and firmly depending on the test application. Misconnection may cause very dangerous situation because of residual high voltage. 12. Never fail to watch the unit, the lightening surge simulator, and EUT in operation.
  • Page 12: Appearance Of The Unit

    ① ① ① ① ① SURGE IN CONNECTOR [SURGE IN: HOT, COM]: Used for inputting surge from the lightning surge simulator. Connect [HOT] to [L1] of LSS-6000 series and [COM] to [L2] by the surge connecting cable. When using LSS-6230, the HOT and COM sides shall be connected to the L and N ②...
  • Page 13 (of the surge simulator’s accessory) to [2]. ⑩ ⑩ ⑩ ⑩ PE TERMINAL [PE]: Protective Earth terminal of the unit. Never fail to connect [PE] to FG terminal of the lightening surge simulator (LSS-6000 series) by PE cable (accessory).
  • Page 14: How To Connect Equipment

    7. HOW TO CONNECT EQUIPMENT 7-1 Connection of Rear Panel Connect PE terminal to FG terminal of LSS-6000 series by PE cable (accessory) as indicating in the figure below. Connect the interlock connector [1] to the LSS-6000 series interlock connector by the interlock cable (accessory).
  • Page 15: Connection Of The Front Panel

    7-3 Connection of the front panel (in case of LSS-6230) Connection of the LSS-INJ6400SIG to the LSS-6230 is done by using the supplied Surge In Cable. Connect the safety socket side of the cables to the SURGE IN terminals on the LSS-INJ6400SIG and solderless terminal side to the EUT LINE OUPTUT (L, N) terminals on the LSS-6230.
  • Page 16: Setting When Arrestors

    7-3 Setting When Arrestors Coupling (1) To inject surge to Line - Line Example: In case of injection line: [OUT1] and return line: [OUT2] SURGE RETURN SURGE INJ LINE SELECT LINE SELECT LINE IN OUT1 SURGE PROTECTION OUT2 OUT3 OUT4 INDUCTORS BY-PASS C A P A C I T O R S...
  • Page 17 (2) To inject surge to Line-Ground Example: In case of injection line: [OUT1] and return line: [GND]. SURGE RETURN SURGE INJ LINE IN LINE SELECT LINE SELECT OUT1 SURGE PROTECTION OUT2 OUT3 OUT4 INDUCTORS BY-PASS C A P A C I T O R S A R R E S T O R S C O U P L I N G C O U P L I N G...
  • Page 18: Setting Whenc

    7-4 Setting When Capacitors Coupling (1) To inject surge to Line - Line Example: In case of injection line: [OUT1] and return line: [OUT2] SURGE RETURN SURGE INJ LINE SELECT LINE SELECT LINE IN OUT1 SURGE PROTECTION OUT2 OUT3 OUT4 INDUCTORS BY-PASS C A P A C I T O R S...
  • Page 19 EUT. Besides, the surge may not inject to EUT. When using the unit, never fail to turn off the line switch of LSS-6000 series. If AC or DC power is supplied to [HOT] and [COM] terminals of the unit from...
  • Page 20: Block Chart

    8. BLOCK CHART INTERLOCK of the door アクリル扉部インターロックスイッチ INTER LOCK1 SURGE IN 4 0 Ω C A P A C I T O R S A R R E S T O R S INTER LOCK2 C O U P L I N G C O U P L I N G 0 .
  • Page 21: Specifications

    9. SPECIFICATIONS Items Specifications Note Surge Input Voltage 500V-6600V(Combination Wave) EUT Capacity DC50V/1A The Number of Lines (Max.) 4 lines Decoupling Coil 20mH / each line Matching Resistance 40Ω ± 10% Dimension W (488) x H(456) x D(550)mm Weight Approximately 45kg The specifications and functions of the unit are subject to change without prior notice.
  • Page 22: Accessories

    10. ACCESSORIES A A A A B B B B C C C C D D D D E E E E F F F F G G G G H H H H I I I I J J J J A: Accessory bag ...................
  • Page 23: Warranty

    11. WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. 1. Scope The following terms shall apply only to products made by the Company. 2.
  • Page 24 Limited warranty Noise Laboratory Co., Ltd. (hereafter referred to as the Company) warrants its products to be free from defects in materials and workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
  • Page 25 12. MAINTENANCE 1. When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. 2. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. 3.
  • Page 26 13. NOISE LABORATORY SUPPORT NETWORK If a symptom which seems a trouble is found, inform the model name and serial number of the product together with the symptom to Noise Laboratory or your nearest sales agent of Noise Laboratory. When the product is returned to Noise Laboratory, write the state of the trouble, contents of your request, mode name and serial number in a repair order, and pack the product and repair order sheet in the former package of equivalent suitable for transit and send them back.
  • Page 27 NOISE LABORATORY CO., LTD. 1-4-4, Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref., 252-0237, Japan TEL: +81-(0)42-712-2051 FAX: +81-(0)42-712-2050 URL: http://www.noiseken.co.jp Printed in Japan...

This manual is also suitable for:

Lss-inj6400sig

Table of Contents