NoiseKen ESS-801 Instruction Manual

Esd test environment

Advertisement

Quick Links

INSTRUCTION MANUAL
IEC 61000-4-2
ESD TEST ENVIRONMENT
MODEL
Description
Test table
Insulation sheet
Vertical coupling plane
Horizontal coupling plane
Ground plane
Cable with discharge resistors
NOISE LABORATORY CO LTD.
ESS-801
MODEL
03-00039A
03-00004A
03-00005A
03-00020A
03-00007A
05-00054B
5.01Edition
AEC00004-00E-4B

Advertisement

Table of Contents
loading

Summary of Contents for NoiseKen ESS-801

  • Page 1 INSTRUCTION MANUAL IEC 61000-4-2 ESD TEST ENVIRONMENT ESS-801 MODEL Description MODEL Test table 03-00039A Insulation sheet 03-00004A Vertical coupling plane 03-00005A Horizontal coupling plane 03-00020A Ground plane 03-00007A Cable with discharge resistors 05-00054B NOISE LABORATORY CO LTD. 5.01Edition AEC00004-00E-4B...
  • Page 2 NOTICE • The contents of this instruction manual are subject to change without prior notice. • No part of this instruction manual may be reproduced or distributed, in any form or by any means, without the authorization of Noise Laboratory Co., Ltd. •...
  • Page 3: Important Safety Precautions

    1. IMPORTANT SAFETY PRECAUTIONS The following instructions form an integral part of this product and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be observed. This instruction manual should be kept the place the operator can always consult it. This product is originally intended to be used as a ready ESD test test-up for table-top equipment to the EN/IEC 61000-4-2 standard.
  • Page 4 Memorandum...
  • Page 5: Application Form For Instruction Manual

    2. APPLICATION FORM FOR INSTRUCTION MANUAL To: Noise Laboratory Co., Ltd. We place an order for an instruction manual. ESD Test Environment Product: ESS-801 Model: Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No.: Cut off this page "APPLICATION FORM FOR INSTRUCTION MANUAL"...
  • Page 6 Memorandum...
  • Page 7: Table Of Contents

    3. CONTENTS 1. IMPORTANT SAFETY PRECAUTIONS ................... 1 2. APPLICATION FORM FOR INSTRUCTION MANUAL ............3 3. CONTENTS ..........................5 4. PREFACE ..........................7 5. BASIC SAFETY PRECAUTIONS ..................... 8 5-1. Hazard symbols ........................8 5-2. Fundamental Safety Precautions ..................8 6.
  • Page 8 Memorandum...
  • Page 9: Preface

    NoiseKen ESD simulators. Features 1. In combination with the NoiseKen ESD simulator, this product offers a ready-made test environment for ESD tests as per the EN/IEC 61000-4-2 standard. 2. Made by wood, the test table minimizes the loss of energy produced by the simulator, leading to...
  • Page 10: Basic Safety Precautions

    5. BASIC SAFETY PRECAUTIONS 5-1. Hazard symbols It expresses a WARNING. WARNING indicates a potentially hazardous situation death or serious which, if not avoided, could result in injury. 【WARNING labels may be present on the associated equipment you use. Please be sure to refer to the safety precautions provided in the relevant product manual.】...
  • Page 11 5.BASIC SAFTY PRECAUTIONS Never step on or sit on the table. Never use the product as unintended. 【Precautions for handling】 The test table is made of wood. Avoid using or storing this product in a high or low temperature, or high humidity environment. (Operating temperature range: 15~35°C/ Operating humidity range: 25~75%).
  • Page 12: Specifications

    6. SPECIFICATIONS Description Model Dimensions:mm Thickness:mm Quantity Material,Note Top board:lauan plywood 1600 × 800 × 800 legs,beam:poplar ── Test table 03-00039A (Weight :22kg) ※ Load limit :100kg Insulation sheet 03-00004A 1450 × 650 1 sh Polyvinyl chloride Plane:aluminum Vertical coupling 03-00005A 500 ×...
  • Page 13 Memorandum...
  • Page 14: Product Contents

    7. PRODUCT CONTENTS Test table (MODEL 03-00039A) Top board with a horizontal coupling plane ······························································ 1 Legs ················································································································ 2 Beam··············································································································· 2 Legs Top board Beam Wedge ·············································································································· 4 pcs. Retaining block ··································································································· 4 pcs. Retaining block Wedge Insulation sheet 1 sh (MODEL 03-00004A) ··································································...
  • Page 15 Cable with discharge resistors ·································· 2 pcs. (MODEL 05-00054B) Screw M4 with a washer ··················································································· 4 pcs. Cable with discharge resistors Screw M4 Vertical coupling plane (MODEL 03-00005A) Vertical coupling plane ····················································································· 1 sh Stand ············································································································ 2 pcs Center adapter ······························································································· 1 pcs Vertical coupling plane Stand Center adapter...
  • Page 16: Assembling Instructions

    8. ASSEMBLING INSTRUCTIONS 8-1. Assembling the ground plane As the figure shows, align the screw holes of a plane (after ripping off its protective film) to those of the others and fix them by the supplied M3 screws. Screw M3 Ground plane φ4 hole M3 Screw hole...
  • Page 17: Assembling The Test Table

    8-2. Assembling the test table ① Insert the beams to the grooves of the legs (Beams have no direction). Legs Beam...
  • Page 18 ② Insert the retaining blocks to the rails at each corner of the backside of the top board. Each block shall be firmly inserted to the half-depth with the projection outwards. Projection Insert this way Retaining block The Retaining block from the side ③...
  • Page 19 ⑤ Manually insert the wedges to the angle holes of the beams. Proceed for all four corners. flat surface Insert this way flat surface The wedge from the top (illustration not to scale) ⑥ Hit the wedges with a plastic hammer. Important:...
  • Page 20: Operating Precautions

    9. Operating Precautions To ensure safety, the following advices shall be observed. Install the test table on a flat floor surface. After installation, check to see that the 4 legs are in touch with the floor. If the floor is tilted or bumpy, the table may jounce, which may lead to a drop of the object put on the table.
  • Page 21 Memorandum...
  • Page 22: Test Configuration (Inforamative)

    10. TEST CONFIGURATION ( ( ( ( INFORMATIVE) ) ) ) Test configuration for table-top equipment as per the EN/ / / / IEC 61000-4-2 Typical position for indirect discharge to VCP Typical position for direct application Vertical coupling plane Typical position for indirect (0.5m×0.5m) discharge to HCP...
  • Page 23 The center adopter can be used as a positional guide for the indirect discharge test with installing it onto the tip of the conical tip and inserting the vertical coupling plane into the ditch of it. 7. Use the isolation transformer (NoiseKen NCT series Noise Canceller Transformer recommended) for AC line of EUT if necessary.
  • Page 24: Warranty

    11. WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. 1. Scope The following terms shall apply only to products made by the Company. 2.
  • Page 25 Limited warranty Noise Laboratory Co., Ltd. (hereafter referred to as the Company) warrants its products to be free from defects in materials and workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
  • Page 26: Maintenance

    12. MAINTENANCE When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. When cleaning the unit, turn off the switch of this unit and the connected equipment and disconnect the plug socket beforehand.
  • Page 27: Noise Laboratory Support Network

    13. NOISE LABORATORY SUPPORT NETWORK If a symptom that seems a trouble is found, check the symptom against the following check sheet and inform the model name and serial Number of the product together with the symptom to Noise Laboratory or our nearest sales agent in your area. When the product is returned to Noise Laboratory, write the state of the trouble, contents of your request, model name and serial number in a repair order, pack the product and repair order sheet in the former package or equivalent suitable for transit, and send them back.
  • Page 28 NOISE LABORATORY CO., LTD. 1-4-4, Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref., 252-0237, Japan TEL: +81-(0)42-712-2051 FAX: +81-(0)42-712-2050 URL: http://www.noiseken.co.jp Printed in Japan...

Table of Contents