INSTRUCTION MANUAL RADIATION PROBE MODEL 01-00006A 01-00007A 01-00008A 01-00009A 01-00010A 01-00030A 01-00031A 01-00033A 01-00043A 01-00050A N O I S E L A B O R A T O R Y C O . , L T D . E d i t i o n 1 . 0 5...
Page 2
NOTICE The contents of this booklet are subject to change without prior notice. No part of this booklet may be reproduced or transferred, in any form, for any purpose, without the permission of Noise Laboratory Co., Ltd. The contents of this booklet have been thoroughly checked. However, if a doubtful point, an error in writing or a missing is found, please contact us.
1 APPLICATION FORM FOR INSTRUCTION MANUAL We place an order for an instruction manual. Model: 01-000 Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No.: Cut off this page "application form for instruction manual" from this volume and keep it for future use with care.
2 CONTENTS APPLICATION FORM FOR INSTRUCTION MANUAL ....... 1 CONTENTS ..................3 GENERAL DESCRIPTION ..............5 APPEARANCE ..................6 SPECIFICATIONS ................9 O P E R A T I O N ................... 10 WARRANTY ..................12 MAINTENANCE ................. 14 NOISE LABORATORY SUPPORT NETWORK ........15...
3 GENERAL DESCRIPTION Connected to the INS Impulse Noise Simulator, Radiation Probe gives radiated interference to the circuit, PC board or unit to be tested, allowing the user to know where are the parts or blocks which are sensitive to radiated noise.
Parameters Specifications Note ±4000V MAX Input voltage 50ns~ 1μ s Input pulse width 01-00006A: φ 50 mm 01-00007A: φ 75 mm 01-00008A: φ 100 mm 01-00009A: φ 150 mm 01-00010A: φ 200 mm Loop diameter 01-00030A: φ 300 mm 01-00031A: φ 250 mm 01-00033A:...
6 OPERATION ① As shown in the figure, connect the connector of the radiation probe to the PULSE OUT or 50Ω TERM OUT connected to the PULSE OUT via TERM IN terminal. These different connections generate different pulse waveforms and amplitudes.
Page 13
NOTE In case of positive pulse on Impulse Noise Simulator, The loop current direction is indicated by arrow in the following figure. When a negative pulse is applied, the loop current flows opposite. Caution label...
7 WARRANTY Servicing terms The following terms are applicable to servicing by Noise Laboratory Co., Ltd., (hereafter referred to as the Company) provided to maintain the intended performance of its products. Scope The following terms shall apply only to products made by the Company.
Page 15
Limited warranty Noise Laboratory Co., Ltd. (hereafter referred to as the Company) warrants products free from defects materials workmanship under normal use and service for a period of one year from date of delivery. In the event of failure of a product covered by this warranty, the Company will repair the product or may, at its option, replace it in lieu of repair without charge.
8 MAINTENANCE When repair, maintenance or internal adjustment of the unit is required, a qualified service engineer takes charge of such work. Maintenance on the user side is restricted to the outside cleaning and functional check of the unit. When checking or replacing the fuse, turn off the switch of the unit and disconnect the plug socket beforehand.