Grounding
TO PREVENT ELEcTRIc SHOcK AND DEATH
FROM INcORREcT GROUNDING WIRE cONNEcTION:
check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.
Do not modify the power cord plug provided with any motor used with this compressor Pump.
Never remove the grounding prong from the plug. Do not use the motor if the power cord or plug is damaged.
If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Symbology
PSI
Pounds per square inch of pressure
cFM
Cubic Feet per Minute flow
Cubic Feet per Minute flow
ScFM
at standard conditions
NPT
National pipe thread, tapered
NPS
National pipe thread, straight
Double Insulated
Specifications
Type
Required HP
Rated Air Pressure
Speed Range
Recommended Speed
Air Outlet
Air Delivery
@ 1050 RPM
Lubrication
Oil Type
Pump Pulley
Belt Type
Mounting Hole Pattern
Recommended
Mounting Bolts
Overall Dimensions
Sound Level
Item 67698
Single Stage Twin Cylinder; Oil Lubricated
5 HP motor
145 PSI
655 - 1050 RPM
850 RPM
1" –16 UN
17.3 SCFM @ 40 PSI
15.2 SCFM @ 90 PSI
Splash Type with Oil Level Window
SAE 30W non-detergent Air Compressor Oil
(Sold separately)
14-1/2" diameter with double V-groove
A 1600
5-1/4" x 10-1/4" (center-to-center)
Four 7/16" diameter holes
3/8" diameter, grade 5 or better
17-3/4" L x 12-1/4" W x 15" H
89 dB @ 1m
For technical questions, please call 1-888-866-5797.
Canadian Standards Association
Underwriters Laboratories, Inc.
V
Volts
~
Alternating Current
A
Amperes
Page 5