Owner's Manual & Safety Instructions
Save This Manual
operating, inspection, maintenance and cleaning procedures� Write the product's serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number)�
Keep this manual and the receipt in a safe and dry place for future reference�
6
oilless
GAL
air compressor
reV 14h
When unpacking, make sure that the product is intact
and undamaged� If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible�
©
Copyright
2014 by Harbor Freight Tools
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools�
Diagrams within this manual may not be drawn proportionally� Due to continuing
improvements, actual product may differ slightly from the product described herein�
Tools required for assembly and service may not be included�
Keep this manual for the safety warnings and precautions, assembly,
Visit our website at: http://www.harborfreight.com
email our technical support at: productsupport@harborfreight.com
®
� All rights reserved�
read this material before using this product.
Failure to do so can result in serious injury.
SaVe tHiS ManuaL.
Need help?
Do you have a question about the 62380 and is the answer not in the manual?
Questions and answers
Air compressor pressure can't be pumped higher than 30 psi, no air leak found, Is air pump defect or not? how to diagnosis this problem?
A Central Pneumatic air compressor model 62380 not pumping pressure higher than 30 psi could be caused by:
1. Air leaks at fittings: Check all connections using soapy water while the compressor is pressurized. Look for air bubbles indicating leaks and tighten fittings as needed.
2. Loose fittings: Reduce air pressure before checking and tightening connections. Do not overtighten.
3. Compressor not large enough for the tool: Verify if the tool's CFM requirement exceeds the compressor's capacity. If so, a larger compressor is needed.
4. Dirty filters: In dusty environments, clean or replace filters more often to maintain proper airflow.
Diagnosis steps:
- Apply soapy water to all joints and fittings with the compressor pressurized to detect leaks.
- Check if the compressor meets the required CFM for the connected tool.
- Inspect and clean the air filters.
- Ensure the unit is on a level surface and has proper ventilation.
This answer is automatically generated