Srne HES4880S200-H User Manual

Srne HES4880S200-H User Manual

All-in-one solar charge inverter

Advertisement

USER MANUAL
All-in-one solar charge inverter
HES4880S200-H
HES48100S200-H
HES48120S200-H
V1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HES4880S200-H and is the answer not in the manual?

Questions and answers

Summary of Contents for Srne HES4880S200-H

  • Page 1 USER MANUAL All-in-one solar charge inverter HES4880S200-H HES48100S200-H HES48120S200-H V1.0...
  • Page 2: Table Of Contents

    Table of Contents 1. Safety ................................. 4 1.1、How to use this manual ........................4 1.2、Symbols in this manual ........................4 1.3、Safety instructions ..........................4 2. Production Instructions ..........................5 2.1、Instructions ............................5 2.2、Features ..............................5 2.3、System connection diagram ......................6 2.4、Production Overview .......................... 7 3.
  • Page 3 7.2、Troubleshooting ..........................37 8. ProtectionandMaintenance ........................39 8.1、Protection features ........................... 39 8.2、Maintenance ............................40 9. Datasheet ..............................41...
  • Page 4: Safety

    1. Safety 1.1、How to use this manual This manual contains important information、guidelines、operation and maintenance for the • following products:HES series 4880S200-H,48100S200-H、48120S200-H • The manual must be followed during installation and maintenance. 1.2、Symbols in this manual Symbol Description DANGER indicates a hazardous situations which if not avoided will result in △...
  • Page 5: Production Instructions

    2. Production Instructions 2.1、Instructions HES series is a new type of solar energy storage inverter control inverter integrating solar energy storage & utility charging and energy storage, AC sine wave output. It adopts DSP control and features high response speed, reliability, and industrial standard through an advanced control algorithm. Solar generation Battery charging Energy consumption...
  • Page 6: System Connection Diagram

    2.3、System connection diagram The diagram below shows the system application scenario of this product. A complete system consists of the following components: • PV modules: converts light energy into DC energy, which can be used to charge the battery via an inverter or directly inverted into AC power to supply the load.
  • Page 7: Production Overview

    2.4、Production Overview Load terminals LED Indicators (L+N) LCD screen PV1 terminals Touchable key PV2 terminals USB-B port Battery terminals RS485-1 port PV Breaker Parallel communication B port CAN/RS485-2 port (parallel module only) Parallel communication A port Dry contact (parallel module only) Utility terminals ON/OFF Rocker Switch (L+N)
  • Page 8: Installation

    3. Installation 3.1、Select the mount location HES series can be used outdoors (protection class IP65). Please consider the followings before selecting the location: • Choose the solid wall to install the inverter. • Mount the inverter at eye level. • Adequate heat dissipation space must be provided for the inverter.
  • Page 9: Mount The Inverter

    3.2、Mount the inverter Punch 4 mounting holes in the wall with an electric drill according to the specified size, and insert 4 M8*60 expansion screws above. 3.3、Remove the terminal cover & anti insect net Using a screwdriver, remove the terminal protection cover and anti insect net. Fan cover removable for cleaning Terminal Cover...
  • Page 10: Connection

    4. Connection 4.1、Single-phase output AC output Items Description Applicable Model HES series S model Output Voltage Range (L-N) 200~240Vac, 230Vac default ○ NOTICE • Users can change the output phase mode and output voltage by setup menu. Please read the chapter 5.2 Setting.
  • Page 12: Cable & Circuit Breaker Requirement

    4.2、Cable & circuit breaker requirement • PV INPUT Model Cable Diameter Max.PV Input Current Circuit Breaker Spec HES4880S200-H 5mm²/ 10 AWG 2P-25A HES48100S200-H 5mm²/ 10 AWG 2P-25A HES48120S200-H 5mm²/ 10 AWG 2P-25A • AC INPUT Model Output Mode Cable diameter...
  • Page 13 ○ NOTICE • PV INPUT、AC INPUT、AC OUTPUT Use a stripper to remove the 6~8mm insulation of the cable. Fixing a ferrule at the end of the cable. (ferrule needs to be prepared by the user) • BATTERY 1. Use a stripper to remove the 6~8mm insulation of the cable 2.
  • Page 14: Ac Input & Output Connection

    4.3、AC input & output connection Connect the live,neutral and ground wires according to the cables’ position and order shown in the diagram below. △ DANGER Before connecting AC inputs and outputs, the circuit breaker must be opened to avoid the •...
  • Page 15: Pv Connection

    4.5、PV connection Connect the positive and negative wires of the two strings of PV according to the diagram below. DANGER △ • Before connecting PV, the circuit breaker must be opened to avoid the risk of electric shock and must not be operated with electricity. •...
  • Page 16: Grounding Connection

    4.7、Grounding connection Please make sure the grounding terminal connect to the Grounding Bar. ○ NOTICE • The grounding cable should have a diameter of not less than 4 mm² and be as close as possible to the grounding point. 4.8、Final assembly After ensuring that the wiring is reliable and the wire sequence is correct, install the terminal protection cover in place.
  • Page 17: Operation

    5. Operation 5.1、Operation and display panel The operation and display panel below includes 1 LCD screen, 3 indicators, 4 touchable keys.
  • Page 18 • Touchable Keys Touchable Keys Description To enter/exit the setting menu To next selection To last selection To confirm/enter the selection in setting menu • LED Indicators Indicators Color Description Continued: utility grid by-pass output AC/INV Green Flash: inverter output Continued: charging complete CHARGE Yellow...
  • Page 19 • Display panel Icon Description Icon Description Indicates the PV panel Indicates the utility grid Indicates the battery Indicates the generator Indicates the inverter is workin Indicates the home load Indicates the inverter is Indicates the buzzer communicating with data muted collector Indicates the direction of energy flow...
  • Page 20 Icon Description Icon Description Indicates load power Indicates battery SOC 80%~100% 80%~100% Indicates load power Indicates battery SOC 60%~79% 60%~79% Indicates load power Indicates battery SOC 40%~59% 40%~59% Indicates load power Indicates battery SOC 20%~39% 20%~39% Indicates load power Indicates battery SOC 5%~19% 5%~19% Indicates battery under-voltage Battery over-discharge...
  • Page 21 View real-time data • In the main screen,press the UP / DOWN keys to view the real-time data of the inverter during operation. ○ NOTICE UP/DOWN Main Screen View Real-Time Data Real-Time Data Page PV side BAT side AC IN side LOAD side General PV voltage...
  • Page 22: Setting

    5.2、Setting ○ NOTICE UP/DOWN UP/DOWN Parameter option Parameter ID Parameter Meaning Options Description Exit the setup menu. Exit Utility at first priority, utility and solar provide power to load at the same time when solar is UTI default available, battery will provide power to load only when utility power is not available.
  • Page 23 参数含义 选项 描述 When output range is 220/230V, input voltage UPS default range 170~280V AC input voltage When output range is 220/230V, input voltage range range 90~280V When parameter1= SBU=SOL, output source Voltage point of will switch to utility from battery when the 43.6 default battery switch to battery voltage below the preset value.
  • Page 24 Parameter Meaning Options Description Setting range: 48V~58.4V, parameters Battery float charging cannot be set only after successful BMS 55.2 default voltage communication. When the battery voltage falls below this voltage point and parameter 13 value is Battery overdischarge reached, the inverter output will be switched 42 default off.Setting range: 40V~48V, increment of each voltage (delay off...
  • Page 25 参数含义 选项 描述 When overload occurs and the output is switched off,the machine will not restart. When overload occurs and the output is Over-load restart switched off,the machine will restart after a delay of 3 minutes. After it reaches 5 ENA default cumulative time, the machine will not restart automatically.
  • Page 26 参数含义 选项 描述 Setting range: 00:00:00-23:59:00 1st slot start charging 00:00:00 Setting range: 00:00:00-23:59:00 1st slot end charging 00:00:00 Setting range: 00:00:00-23:59:00 2nd slot start charging 00:00:00 Setting range: 00:00:00-23:59:00 2nd slot end charging 00:00:00 Setting range: 00:00:00-23:59:00 3rd slot start charging 00:00:00 Setting range: 00:00:00-23:59:00 3rd slot end charging...
  • Page 27: Ac Output Mode

    5.3、AC output mode The AC output mode corresponds to parameter setting item 01 and 34, which allows the user to set the AC output power source manually. 01 UTI (default) Utility Priority Output • Utility at first priority, utility and solar provide power to load at the same time when solar is available, battery will provide power to load only when utility power is not available.(Priority: utility>solar>battery) Utility Outage Utility Valid...
  • Page 28: Battery Charging Mode

    5.4、Battery charging mode The charging mode corresponds to parameter setting item 06, which allows the user to set the charging mode manually. SNU (default) Hybrid Charging • Solar and utility charging the battery at the same time, solar at the first priority, utility power as a supplement when solar power is not sufficient.
  • Page 29: Time-Slot Charging/Discharging Function

    5.5、Time-slot charging/discharging function The HES series is equipped with a time-slot charging and discharging function, which allows users to set different charging and discharging periods according to the local peak and valley tariffs, so that the utility power and PV energy can be used rationally. When mains electricity is expensive, the battery inverter is used to carry the load;...
  • Page 30: Battery Parameter

    5.6、Battery parameter Lead-acid battery • Sealed Flooded User-defined Parameter/Battery type Over-voltage cut-off voltage Equalization charging voltage 56.8V 40~60V settable Bulk charging voltage 57.6V 56.8V 57.6V 40~60V settable Float charging voltage 55.2V 55.2V 55.2V 40~60V settable Under-voltage alarm voltage 40~60V settable Under-voltage cut-off voltage 40~60V settable...
  • Page 31 Li-ion batter • Ternary Userdefined Parameter/Battery type Over-voltage cut-off voltage 40~60V Equalization charging voltage settable 40~60V Bulk charging voltage 53.2V 57.6V 56.8V 53.2V 49.2V settable 40~60V Float charging voltage 53.2V 57.6V 56.8V 53.2V 49.2V settable 40~60V Under-voltage alarm voltage 43.6V 46.8V 49.6V 46.4V...
  • Page 32: Communication

    6. Communication 6.1、Overview USB-B port RS485-1 port RS485-2 port Parallel connection port Dry contact port (reserved port, this model does not support parallel connection) 6.2、USB-B port USB typeB USB2.0 printer cable The user can read and modify device parameters through this port by using the host software. Please contact us for the host software installation package if you require one.
  • Page 33: Rs485-1 Port

    6.3、RS485-1 port The RS485-1 port is used to connect to the Wi-Fi/GPRS data acquisition module, which allows the user to view the operating status and parameters of the inverter via the mobile phone APP. RJ45 Definition Pin 1 Pin 2 Pin 3 Pin 4 Pin 5...
  • Page 34: Dry Contact

    6.5、Dry contact Dry contact port with 4 functions: 1. Remote switch on/off 2. Switching signal output 3. Battery temperature sampling 4. Generator remote start/ stop Switching signal output Temperature sampling(reserved) Remote on/off Generator remote on/off Function Description When pin 1 is connected with pin 2, the inverter will switched off the AC Remote switch on/off output.
  • Page 35: Faultandremedy

    7. FaultandRemedy 7.1、Fault code Alarm Fault code Fault Does it Affect the Instructions Meaning Code outputs Battery under-voltage alarm BatVoltLow Battery discharge over-current, software BatOverCurrSw protection Battery disconnected alarm BatOpen Battery under-voltage stop discharging BatLowEod alarm Battery over-current hardware protection BatOverCurrHw Battery over-voltage protection BatOverVolt...
  • Page 36: Troubleshooting

    Fault Code Meaning Does it Affect the Instructions outputs ModelNumErr Wrong model Busdiff Busbar voltage imbalance BusShort Busbar short circuit Rlyshort Inverter output back flow to bypass LinePhaseErr Utility input phase fault BusVoltLow Busbar under-voltage protection Battery SOC below 10% alarm (Only BatCapacityLow1 enable BMS take effect) Battery SOC below 5% alarm (Only...
  • Page 37 Fault Code Meaning Causality Remedy Manual reset: Power off and restart. The battery voltage is lower Automatic reset: charge the battery so that Battery over-discharge than the value set in the the battery voltage is higher than the value parameter [12]. set in the parameter item [35].
  • Page 38: Protectionandmaintenance

    8. ProtectionandMaintenance 8.1、Protection features Protection Feature Instruction When the charging current or power of the PV array configured PV input current/power exceeds the PV input rated value, the inverter will limit the input limiting protection power and charge at the rated. If the PV voltage exceeds the maximum value allowed by the PV input over-voltage hardware, the machine will report a fault and stop the PV boost to...
  • Page 39: Maintenance

    Bypass over-current Built-in AC input over-current protection circuit breaker. protection When the phase of the bypass input and the phase of the inverter split do not match, the inverter disables switching to the bypass Bypass phase inconsistency protection output to prevent the load from dropping out or short-circuiting when switching to the bypass.
  • Page 40: Datasheet

    9. Datasheet MODEL HES4880S200-H HES48100S200-H HES48120S200-H BE SET INVERTER OUTPUT Rated Output Power 8,800W 10,000W 12000W Max.Peak Power 17,600VA 20,000VA 24,000VA Rated Output Voltage 230Vac(Single phase) Load Capacity of Motors Rated AC Frequency 50/60Hz Waveform Pure Sine Wave Switch Time 10ms(typical)...
  • Page 41 Cooling Method Internal Fan Warranty 5 Years COMMUNICATION Embedded Interfaces RS485 / CAN / USB / Dry contact External Modules Wi-Fi / GPRS (Optional) CERTIFICATION Safety IEC62109-1, IEC62109-2,UL1741 EN61000-6-1, EN61000-6-3, FCC 15 class B RoHS...