Combustion, Dilution & Ventilation Air - Lennox ELITE Series Installation Instructions Manual

Gas furnace upflow / horizontal air discharge
Table of Contents

Advertisement

D
Do not install the furnace where drafts might blow direct­
ly into it. This could cause improper combustion and un­
safe operation.
Do not block the furnace combustion air openings with
D
clothing, boxes, doors, etc. Air is needed for proper
combustion and safe unit operation.
When the furnace is installed in an attic or other insu­
D
lated space, keep insulation away from the furnace.
• Please consult the manufacturer of your evaporator coil
for their recommendations on distance required
between the heat exchanger and their drain pan. Ad­
equate space must be provided between the drain pan
and the furnace heat exchanger.
NOTE - The Commonwealth of Massachusetts stipu­
lates these additional requirements:
Gas furnaces shall be installed by a licensed plumb­
D
er or fitter only.
The gas cock must be "T handle" type.
D
When a furnace is installed in an attic, the passage­
D
way to and service area surrounding the equipment
shall be floored.
WARNING
The State of California has determined that this prod­
uct may contain or produce a chemical or chemicals,
in very low doses, which may cause serious illness
or death. It may also cause cancer, birth defects or
reproductive harm.
Combustion, Dilution & Ventilation Air
In the past, there was no problem in bringing in sufficient
outdoor air for combustion. Infiltration provided all the air
that was needed. In today's homes, tight construction prac­
tices make it necessary to bring in air from outside for com­
bustion. Take into account that exhaust fans, appliance
vents, chimneys, and fireplaces force additional air that
could be used for combustion out of the house. Unless out­
side air is brought into the house for combustion, negative
pressure (outside pressure is greater than inside pressure)
will build to the point that a downdraft can occur in the fur­
nace vent pipe or chimney. As a result, combustion gases
enter the living space creating a potentially dangerous situ­
ation.
In the absence of local codes concerning air for combus­
tion and ventilation, use the guidelines and procedures in
this section to install EL280UH furnaces to ensure efficient
and safe operation. You must consider combustion air
needs and requirements for exhaust vents and gas piping.
A portion of this information has been reprinted with per­
mission from the National Fuel Gas Code (ANSI‐Z223.1).
This reprinted material is not the complete and official posi­
tion of the ANSI on the referenced subject, which is repre­
sented only by the standard in its entirety.
Do not install the furnace in a corrosive or contami­
nated atmosphere. Meet all combustion and ventila­
tion air requirements, as well as all local codes.
Insufficient combustion air can cause headaches,
nausea, dizziness or asphyxiation. It will also cause
excess water in the heat exchanger resulting in rust­
ing and premature heat exchanger failure. Excessive
exposure to contaminated combustion air will result
in safety and performance related problems. Avoid
exposure to the following substances in the com­
bustion air supply:
Permanent wave solutions
Chlorinated waxes and cleaners
Chlorine base swimming pool chemicals
Water softening chemicals
De‐icing salts or chemicals
Carbon tetrachloride
Halogen type refrigerants
Cleaning solvents (such as perchloroethylene)
Printing inks, paint removers, varnishes, etc.
Hydrochloric acid
Cements and glues
Antistatic fabric softeners for clothes dryers
Masonry acid washing materials
All gas‐fired appliances require air for the combustion pro­
cess. If sufficient combustion air is not available, the fur­
nace or other appliances will operate inefficiently and un­
safely. Enough air must be provided to meet the needs of
all fuel‐burning appliances and appliances such as ex­
haust fans which force air out of the house. When fire­
places, exhaust fans, or clothes dryers are used at the
same time as the furnace, much more air is necessary to
ensure proper combustion and to prevent a downdraft. In­
sufficient air causes incomplete combustion which can re­
sult in carbon monoxide.
In addition to providing combustion air, fresh outdoor air di­
lutes contaminants in the indoor air. These contaminants
may include bleaches, adhesives, detergents, solvents
and other contaminants which can corrode furnace compo­
nents.
The requirements for providing air for combustion and ven­
tilation depend largely on whether the furnace is installed in
an unconfined or a confined space.
Unconfined Space
An unconfined space is an area such as a basement or
large equipment room with a volume greater than 50 cubic
3
feet (1.42 m
) per 1,000 Btu (.29 kW) per hour of the com­
bined input rating of all appliances installed in that space.
This space also includes adjacent rooms which are not
separated by a door. Though an area may appear to be un­
Page 5
CAUTION
CAUTION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite el280uh

Table of Contents