Installation; Installing/Replacing The Lamp; Rigging - EuroLite Pinspot PAR36 User Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Installing/Replacing the lamp

Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
Please follow the lamp manufacturer's notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 6 V/30 W PAR36 lamp.
During the operation, the lamp reaches temperatures of up to 120° C.
Procedure:
Step 1: Please remove the fixation ring by pressing it together.
Step 2: If replacing the lamp, remove the old lamp from the pinspot and loosen the wires. Step
3: Loosen the screws on the new 6 V/30W PAR36 lamp with an appropriate screwdriver. Step
4: Connect the wires with the lamp using an appropriate screwdriver.
Step 5: Tighten the screws.
Step 6: Insert the lamp in the housing.
Step 7: Fix the lamp with the fixation ring.

Rigging

Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the Pinspot has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Disconnect from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
DANGER TO LIFE!
14/18

Advertisement

Table of Contents
loading

Table of Contents