FUSE FLOW RATE (25°C SAE-30 OIL) WEIGHT WIRE SIZE ** CODE TYPE VOLT 164 930 12-US OCK1 Ø6 Ø8 Ø13 164 930 13-US ** Length up to 6.6 ft IP 67 Protection APPLICATIONS There are numerous fields of applications for the pump, however only exclusively with the allowed liquids mentioned: Ø...
AMBIENT CONDITIONS TEMPERATURE: min.-10°C 14°F-max.60°C 140°F RELATIVE HUMIDITY: max. 90 % WARNING: the above indicated temperature ranges are applicable to all components of the pump and these limits must be respected in order to avoid any possible damage or malfunctioning. OPERATING CYCLE The pump can operate on a continuous cycle with the following conditions: Ø...
Page 5
To ensure the correct directional flow of the fluid as indicated by the arrow on the top plate, it is necessary to connect the positive pole (+) of the battery supply to the red wire on the motor end-cap and the negative pole (-) to the black wire. Electrical connections must be made using adequate terminal blocks and connectors ensuring a tight fitment of the electrical cables.
TROUBLESHOOTING CHECK POINTS IF THE PUMP HAS STOPPED OR WILL NOT START Ø Check the effectiveness of the battery power supply (voltage activity); Ø Check if the fuse has blown; Ø Check for any foreign matter present in the pump body. To do this, disconnect the power supply and unscrew the four fixing screws, remove the front cover plate and inspect the chamber.
5) The Warranty does not cover any related installation costs involved. 6) Transport costs are refundable only in the case where warranty has been duly accepted by Marco Spa and they will be limited to the actual shipment costs between Marco Spa warehouse and the client's delivery address.
Page 8
MOUNTING SEQUENCE Mount the isolators (2) on the pump (1); Screw the hose fitting (4) complete with OR (3), on the pump (1); Fit the hose clamp (5) on the hose (6); Connect the hose (6) on the hose fitting (4) and screw the hose clamp (5); Screw the quick fitting (7) on the pump body (1);...
Page 9
EXPLODED VIEW RILSAN TUBE RELEASE Pos. Q.ty Description Pos. Q.ty Description PUMP RILSAN TUBE Ø 8/6 L=0,3 m ANTIVIBRATION MOUNT COUPLING O-RING RILSAN TUBE Ø 6/4 L=1,2 m TUBE OUTLET BATTERY (NOT INCLUDED) HOSE CLAMP RED CROCODILE CLIP TUBE BLACK CROCODILE CLIP QUICK FIT 7,5 A FUSE RILSAN TUBE Ø...
Page 13
E.C. DECLARATION OF CONFORMITY We confirm that the product: 164 930 12-US OCK1 12V Oil Change Kit 164 930 13-US OCK1 24V Oil Change Kit is in conformity with the Directive 2004/108/EC (ex.89/336/EC) relating to Electromagnetic Compatibility. This declaration is valid for all products which are produced in accordance with the technical documentation which is a part of this declaration.
Page 16
Questo documento e' proprieta' di Marco S.p.A la riproduzione e l'uso sono vietati. Tutti i diritti sono riservati. Per ulteriori informazioni vedere nostro sito internet - www.marco.it Marco S.p.A Via Mameli 10 - 25014 Castenedolo (Brescia) – Italia tel. +39 030 2134.1 / Fax +39 030 2134.300 Property of MARCO S.p.A reproduction prohibited.