  • Page 1 Operating instructions Through-beam sensor OGE3xx OGS3xx OGE5xx OGS5xx...
  • Page 2: Functions And Features

    1 Functions and features The through-beam sensor detects objects and materials without contact and indicates their presence by a switching signal. For the range see the type label. 2 Installation transmitter receiver ► Install the receiver (OGE...) and secure it to a bracket. ►...
  • Page 3: Operating And Display Elements

    4 Operating and display elements transmitter receiver 1: LED 2: [OUT off] 3: [OUT on] 4 Settings 4.1 The receiver is to switch when the object is detected ► Position the object. receiver transmitter ► Press [OUT on] for 2 s. > The sensitivity is set to the object. >...
  • Page 4: Operation

    The settings can also be carried out first without object and then with object. 4.3 Programming unsuccessful > LED flashes quickly, 8 Hz. Possible causes • Insufficient difference in measurements. • Max. programming time of 15 min. exceeded. 4.4 Setting of maximum sensitivity ►...