Graco 245866 Instructions Manual page 5

Heated hose kit
Table of Contents

Advertisement

Fluid Heater
Order separately a VISCON HP heater that meets local electrical and hazardous location requirements.
Hazardous Location Heaters
Part No.
Series
245848*
A
245862
A
245863
A
245864
A
246254
A
*
Heater 245848 can only be used with a total heated hose length of 150 ft. (45.7 m) or less.
Non-hazardous Location Heaters
Model No.
Series
245867*
A
245868
A
245869
A
245870
A
246276
A
Heater 245867 can only be used with a total heated hose length of 150 ft. (45.7 m) or less.
*
309525C
VAC (50/60 Hz single phase) / Watts / Amps
120 / 2300 / 19.2
200 / 4000 / 20.0
240 / 4000 / 16.7
480 / 4000 / 8.30
380 / 4000 / 10.5
VAC (50/60 Hz single phase) / Watts / Amps
120 / 2300 / 19.2
200 / 4000 / 20.0
240 / 4000 / 16.7
480 / 4000 / 8.30
380 / 4000 / 10.5
Heated Hose Components
Approvals
II 2 G
Approved EEx d II B T2 482° F (250° C)
Certificate No. ISSeP02ATEX051
Approved to EN50014 and EN50018 for Hazardous
Locations, Temp Code T2 482° F (250° C). See
Technical Data in your heater manual for additional
information.
CSA Certified and FM Approved as flame proof for
Class I, Division 1, Group D Hazardous Locations,
Temp Code T2 482° F (250° C), Maximum Ambient
Operating Temperature = 135° (57° C). See
Technical Data in your heater manual for additional
information.
Approvals
Conforms to
UL Std. 61010-1
CSA Std. 22.2 No. 1010-1-92
5