Item number Item name
802
DIGITAL AUDIO MUTE IN
SHUTTLE MODE
805
AUDIO MONITOR
OUTPUT MIXING
806
LEVEL METER SCALE
807
AUDIO OUTPUT PHASE
808
INTERNAL AUDIO
SIGNAL GENERATOR
809
AUDIO LEVEL METER
DIMMER CONTROL
Menu items in the 800s, relating to audio control
Settings
Set the digital audio muting conditions during shuttle playback.
OFF : Not muted.
CUEUP: Muted during cue-up or preroll operations.
FULL: Muted in shuttle mode.
Select the audio mixing method used for digital audio signals supplied to the
MONITOR OUTPUT connector.
ADD: Simple addition.
RMS : Root-mean-square.
AVE: Simple average.
Select the mode in which digital audio levels are displayed.
PEAK0 : Displays the audio level as negative values with the maximum level set
to 0 dB.
REF 0: Displays the audio level as positive and negative values with the
reference level set to 0 dB.
Select the output timing of a digital audio playback signal (SDI and AES/EBU
only). The reference position corresponds to a setting of 80H; when the setting
is less than 80H, the output timing is advanced, and when it is higher than 80H,
the output timing is delayed. (80H, 128 samples = approx. 2.7 ms, and 80H, 1
sample=approx. 20 µs)
0 ... 80 ... FF : Setting in this range.
Select the operation of the internal audio test signal generator. When a setting
other than "OFF" is selected, the signal from the internal audio test signal
generator is output to all of the audio channels.
OFF : No operation.
SILNC: Silent signal.
1KHZ: At 1 kHz, –20 dB FS sine wave is supplied to all audio input channels.
Set the brightness of the audio level meters.
0 ... 7: Set in this range. 0 is the brightest, and 7 the dimmest.
6-17