Whirlpool L30P Installation And Operation Manual page 21

Demand controlled water softener
Table of Contents

Advertisement

RESETTING TO FACTORY DEFAULTS
To reset the electronic controller to its factory default
for all settings (time, hardness, etc.):
1. Press the PROGRAM button and hold it until the
display changes twice to show the flashing model
code.
r
2. Press the
UP button (a few times, if necessary)
to display a flashing "SoS".
3. Press the PROGRAM button, and the electronic
controller will restart.
4. Set the present time, hardness, etc., as described
on pages 12 & 13.
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make the
initial checks, and the manual initiated
diagnostics.
NOTE: The electronic control display must show a
steady time (not flashing). If an error code
shows, first press the PROGRAM button to
enter the diagnostic display.
1. Press the RECHARGE button and hold in for 3
seconds. RECHARGE begins to flash as the
softener's valve advances from the service to fill
position. Shine a flashlight down the brinewell and
observe fill water entering the tank.
If water does not enter the tank, look for an
obstructed nozzle, venturi, fill flow plug, brine
tubing, or brine valve riser pipe.
Need help troubleshooting? Call Toll Free 1-866-986-3223
When you call, please be prepared to provide the model and serial number,
found on the rating decal, typically located on the rim below the salt lid hinges.
Troubleshooting
FIG. 37
21
2. After observing fill, press the RECHARGE button to
move the softener's valve into the brine position. A
slow flow of water to the drain will begin. Verify
brine draw from the brine tank by shining a
flashlight into the brinewell and observing a
noticeable drop in the liquid level. This may take 15
to 20 minutes.
NOTE: Be sure water is in contact with the salt, and
not separated by a salt bridge (See "Breaking
A Salt Bridge" section).
If the water softener does not draw brine, check for
(most likely to least likely):
= Dirty or plugged nozzle and venturi, see
"Cleaning the Nozzle and Venturi" section.
= Nozzle and venturi not seated on the gasket, or
gasket deformed.
= Valve seals leaking (See Troubleshooting).
= Restriction in valve drain, causing a backpressure
(bends, kinks, elevated too high, etc.). See
"Install Valve Drain Hose" section.
= Obstruction in brine valve or brine tubing.
NOTE: If water system pressure is low, a too-long or
elevated drain hose may cause backpressure,
stopping brine draw. Avoid drain hose runs
longer than 30 feet. Avoid elevating the hose
more than 8 feet above the floor.
3. Press the RECHARGE button to move the softener's
valve into the backwash position. Look for a fast
flow of water from the drain hose. Check that the
drain can adequately handle the flow and volume.
An obstructed flow indicates a plugged top
distributor, backwash flow plug, or drain hose.
4. Press the RECHARGE button to move the softener's
valve into the fast rinse position. Again look for a
fast drain flow. Allow the softener to rinse for a few
minutes to flush out any brine that may remain in
the resin tank from the brining cycle test.
5. To return the softener's valve to the service
position, press the RECHARGE button.
whirlpoolwatersolutions.com
or visit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Whes33Whes30L33p

Table of Contents