Figure 7-2 Entering The Motor Data - Siemens SIMOTICS FD 1LP1 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

5. Enter the appropriate motor data in the "Motor data" table in the "Value" column.
6. Click "Continue" to confirm your entries.
SIMOTICS FD 1LP1
Operating Instructions 01/2019
– You can find the values for parameters p304...p311 on the motor rating plate.
– The value for parameter p335 (motor cooling method) is encrypted from the motor order
number:
Motor order number
1LL1
1LP1
1LM1/1MM1
1LQ1/1MQ1
1LH1/1MH1
1LN1/1MN1
Figure 7-2
Entering the motor data
7.11 Setting the motor parameters at the converter
Cooling method
IC01
IC06
IC411
IC416
IC71W
IC86W
Start-up
Parameter p335
0
1
4
5
6
6