 3 steps to start operation
1. Press
to start or stop the operation.
2. Press
to select the operation mode.
The operation mode changes as follows.
AUTO
COOL
3. Press
to set the desired temperature.
The temperature changes by 0.5 °C increments.
Temperature setting range
Auto/Cooling/Dry
Heating
NOTES:
• In the Cooling or Dry mode, set the temperature lower than the
current room temperature.
• In the Cooling mode, the indoor unit fan may stop from time to time
to perform Fan control for energy saving that enables power-saving
operation by stopping the rotation of the indoor unit fan when the
outdoor unit is stopped.
In initial setting, this function is activated.
To deactivate the function, consult the installer or authorized service
personnel.
• In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation
when necessary.
• In the Fan mode, temperature control is not available.
 Temperature unit switching
1. Press
until only the clock is displayed.
2. Press down
The current temperature unit will be displayed. (Factory setting: °C)
3. Press
to switch the temperature unit. (°C ⇔ °F)
4. Press
to fi nish the setting.
If you do not press the button for 30 seconds, the displayed
temperature unit will be set.

5. AIRFLOW SETTINGS

5.1. Fan speed setting

Press
to control the fan speed.
The fan speed changes as follows.
(Auto)
(High)
When
is selected, the fan speed depends on the operating
condition.
To increase the air cleaning effect, set the fan speed to High.
5.2. Airfl ow direction setting
For details of the airfl ow ranges, refer to "Airfl ow direction
range".
 Vertical airfl ow direction setting
Press
to adjust the vertical airfl ow direction.
En-5
DRY
FAN
HEAT
18.0 to 30.0 °C
16.0 to 30.0 °C
for more than 5 seconds.
(Med)
(Low)
(Quiet)
 Horizontal airfl ow direction setting
Before you adjust the horizontal airfl ow direction, make
sure that the vertical airfl ow direction louver has been
stopped completely.
Adjust two knobs by hand.
 Swing operation setting
Press
to start/stop the Swing operation.
NOTES: The Swing operation may stop temporarily when the indoor
unit fan is rotating at very low speed or is stopped.
 Airfl ow direction range
Vertical airfl ow direction
Change by
Swing operation by
Cooling, Dry
Heating
Fan *
* The Swing operation range depends on the airfl ow direction set before
the Swing operation.
NOTES:
• Do not adjust the airfl ow direction louvers by hand.
• In the Auto or Heating mode, the airfl ow direction stay position 1 for
a while from the start of the operation.
• In the Cooling or Dry mode, position 1-3 is recommended to prevent
condensation drips damaging your property. If position 4-6 keeps for
30 minutes or more in these modes, the airfl ow direction changes to
position 3 automatically.
• When using the mobile app (optional WLAN control is necessary),
the vertical airfl ow can be selected from 4 positions.

6. TIMER OPERATIONS

NOTES: When [
] indicator on the indoor unit blinks, set the clock
and timer again. This blinking shows that the internal clock go
wrong due to an interruption of the power supply. (Refer to
page 9.)
 Timer setting procedure
Before setting the timer, please adjust the clock. (Refer to "remote
controller preparation").
1. Press
.
on the remote controller display will blink.
2. Press
to choose timer operation.
(
)
The timer operation will change as follows:
Weekly timer
On timer
[
]
Off timer
[
]
Program timer
[
]
Sleep timer
3. Press
.
4. Set each timer operation.
For details, refer to the following instructions of each timer setting.
CAUTION
1 ⇄ 2 ⇄ 3 ⇄ 4 ⇄ 5 ⇄ 6
1
4
3
6
1
4 or 3
Enables you to set operation
schedules up to 4 setting for each
day of the week.
Starts the operation at your desired
time.
Stops the operation at your desired
time.
Operates as the combination of the
On timer and Off timer.
Supports your comfortable sleep
by moderating the air conditioner
operation gradually.
6