Name Of Parts; Basic Operations - Fujitsu AUTH09KVLA Operation Manual

Table of Contents

Advertisement

3. NAME OF PARTS

For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
When you use the optional remote controller, the operation
procedure may diff er.
*1) Indicator lamps light in the following conditions.
Color
Name
Operation
Green
Timer
Orange
Economy
Green
*2) The lamp lights only when the operation is set from the
wireless remote controller.
En-3
Air intake grille
Air fi lter (in the air intake grille)
Horizontal louvers
*1)
Indicator lamps
Remote control signal receiver
For Manual Auto operation and
Filter indicator reset (Refer to page 9.)
Operation or condition
Normal operation
Timer operation
*2)
Economy operation
10 °C Heat operation

4. BASIC OPERATIONS

NOTES: For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
The operation mode and the temperature setting range are
shown in the following table.
Operation mode
Auto/Cooling/Dry
Heating
■ Auto mode
The air conditioner selects the appropriate operation mode
(Cooling or Heating) according to your room's present
temperature.
Higher than the setting temperature
Close to the setting temperature
Lower than the setting temperature
When Auto mode is fi rst selected, the fan will operate at low speed for
about a few minutes, during which time the indoor unit detects the room
conditions and selects the operation mode.
When the air conditioner has adjusted your room's temperature to near
*2)
the thermostat setting, it will begin monitor operation.
In the monitor operation mode, the fan will operate at low speed. If the
room temperature subsequently changes, the air conditioner will once
again select the appropriate operation (Heating, Cooling) to adjust the
temperature to the value set in the thermostat.
If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (Heating, Cooling, Dry, Fan).
■ Cooling mode
Use to cool your room.
NOTES: Set the temperature lower than the current room temperature.
■ Dry mode
Use for gently cooling while dehumidifying your room.
NOTES:
• You cannot heat the room.
• Set the temperature lower than the current room temperature,
otherwise, the operation will not operate.
• The unit will operate at low speed in order to adjust room humidity.
The indoor unit's fan may stop from time to time. Also, the fan may
operate at very low speed when adjusting room humidity.
• The fan speed cannot be changed manually.
■ Fan mode
Use to circulate the air throughout your room.
NOTES: You cannot set the temperature.
■ Heating mode
Use to warm your room.
NOTES:
• Set the temperature higher than the current room temperature.
• At the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
• The Automatic defrosting operation overrides the Heating operation
when necessary.
• After the start of Heating operation, it takes sometime before the
room gets warmer.
Temperature setting range
18.0 - 30.0 °C
16.0 - 30.0 °C
Room temperature
Cooling mode
Defi ned temper-
Determined by
ature in tempera-
outdoor temperature
ture setting
Heating mode
Operation
Cooling
Determined by outdoor
temperature
Heating

Advertisement