Mist or steam is emitted from the unit.
□ <In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
□ <In the Heating mode> Is [ ] indicator on the indoor unit blinking?
In this case, steam may rise from the outdoor unit because of the
Automatic defrosting operation. (Refer to page 9.)
Outdoor unit emits water.
□ <In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 9.)
The unit operates differently from the remote controller setting.
□ Are the batteries in the remote controller exhausted?
⇒ Replace the batteries.
Operation is delayed after restart.
□ Has the power supply turned from Off to On suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
Immediately stop operation and turn off the electrical breaker in
following cases. Then consult authorized service personnel.
• The problem persists even if you perform these checks or
diagnostics.
• On the indoor unit, [ ] and [
NOTES: For any troubleshooting related to the WLAN control, refer
to the setting manual for WLAN adapter or the mobile app
installed in your smartphone or tablet PC.
En-13
] blink while [
] is blinking fast.
 State of indicator lamps
: The instruction is relating to the WLAN control (optional).
Lighting pattern:
State
Causes and solutions
Automatic defrosting operation
⇒ Please wait until fi nishing the
defrosting (maximum of 15 minutes).
Filter indicator
⇒ Clean the air fi lter and reset the fi lter
sign.
(3 times)
Error code display
⇒ Consult authorized service personnel.
(Fast)
Timer setting error because of Auto
restart
⇒ Reset the clock and timer settings.
Test run operation (for authorized
service personnel only)
⇒ Press
The power to the wireless router is
not on.
⇒ Check that the power to the wireless
router is on.
(Slow)
There is a possibility that the WLAN
adapter is not properly connected
to the wireless router.
⇒ Disconnect the power supply to the
air conditioner (via breaker or plug),
and then re-connect.
The software of the WLAN adapter
is being updated.
During the air conditioner registration
(pairing of WLAN adapter)
Restricted function
 Manual Auto operation and Filter indicator
reset
You can operate the air conditioner with
indoor unit.
Status
Time to keep pressing
In operation More than 3 seconds
Stopping
2 seconds or less
More than 3 seconds and
less than 10 seconds
More than 10 seconds
(Only for servicing.*
*1) In the multi-split connection, the operation mode follows the other
indoor units.
*2) To stop the forced cooling, press this button or
controller.
Blinking,
Any state
page
to quit the test run.
on the
Mode or operation
Stop
Filter indicator reset
1)
Auto *
Forced cooling
2)
)
on the remote
 
See
9
9
-
9
3
-
10
-
11
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asyg07kete

Table of Contents